      Merge branch 'archit/set-timing-work' · 1dfafbc6
      Tomi Valkeinen authored
      
      
      An overlay manager's timings (the manager size, and blanking parameters
      if an LCD manager) are DISPC shadow registers, and they should hence
      follow the correct programming model.
      
      This series makes the video timings an extra_info parameter in manager's
      private data. The interface drivers now apply the timings instead of
      directly writing to registers.
      
      This change also prevents the need to use display resolution for overlay
      checks, hence making some of the APPLY functions less dependent on the
      display. Some DISPC functions that needed display width can also use
      these privately stored timings.
      
      Signed-off-by: default avatarTomi Valkeinen <tomi.valkeinen@ti.com>
      1dfafbc6
    • Archit Taneja's avatar
      OMAPDSS: DISPC: Remove usage of dispc_mgr_get_device() · 81ab95b7
      Archit Taneja authored
      
      
      The functions calc_fclk_five_taps() and check_horiz_timing_omap3() use the
      function dispc_mgr_get_device() to get the omap_dss_device pointer to which
      the manager is connected, the width of the panel is derived from that.
      
      The manager's timing is stored in it's private data in APPLY. This contains
      the latest timings applied to the manager. Pass these timings to
      dispc_ovl_setup() and use them in the above functions. Remove the function
      dispc_mgr_get_device() as it isn't used any more.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      81ab95b7
    • Archit Taneja's avatar
      OMAPDSS: DISPC: Remove omap_dss_device pointer usage from dispc_mgr_pclk_rate() · 3fa03ba8
      Archit Taneja authored
      
      
      The pixel clock rate for the TV manager is calculated by checking the device
      type connected to the manager, and then requesting the VENC/HDMI interface for
      the pixel clock rate.
      
      Remove the use of omap_dss_device pointer from here by checking which interface
      generates the pixel clock by reading the DSS_CTRL.VENC_HDMI_SWITCH bit.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      3fa03ba8
    • Archit Taneja's avatar
      OMAPDSS: APPLY: Remove an unnecessary omap_dss_device pointer · b3d795ab
      Archit Taneja authored
      
      
      The omap_dss_device pointer declared in dss_ovl_setup_fifo() isn't used. Remove
      the pointer variable declaration and it's assignment.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      b3d795ab
    • Archit Taneja's avatar
      OMAPDSS: DPI/HDMI: Apply manager timings even if panel is disabled · fcc36619
      Archit Taneja authored
      
      
      The DPI and HDMI interfaces use their 'set_timing' functions to take in a new
      set of timings. If the panel is disabled, they do not disable and re-enable
      the interface. Currently, the manager timings are applied in hdmi_power_on()
      and dpi_set_mode() respectively, these are not called by set_timings if the
      panel is disabled.
      
      When checking overlay and manager data, the DSS driver uses the last applied
      manager timings, and not the timings held by omap_dss_device struct. Hence,
      there is a need to apply the new manager timings even if the panel is disabled.
      
      Apply the manager timings if the panel is disabled. Eventually, there should be
      one common place where the timings are applied independent of the state of the
      panel.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      fcc36619
    • Archit Taneja's avatar
      OMAPDSS: APPLY: Remove display dependency from overlay and manager checks · 228b2134
      Archit Taneja authored
      
      
      In order to check the validity of overlay and manager info, there was a need to
      use the omap_dss_device struct to get the panel resolution. The manager's
      private data in APPLY now contains the manager timings. Hence, we don't need to
      rely on the display resolution any more.
      
      Pass the manager's timings in private data to dss_mgr_check(). Remove the need
      to pass omap_dss_device structs in the functions which check for the validity
      of overlay and manager parameters.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      228b2134
    • Archit Taneja's avatar
      OMAPDSS: APPLY: Don't check manager settings if it is disabled · 5dd747e8
      Archit Taneja authored
      
      
      If a manager is disabled, there is no guarantee at any point in time that all
      it's parameters are configured. There is always a chance that some more
      parameters are yet to be configured by a user of DSS, or by DSS itself.
      
      However, when the manager is enabled, we can be certain that all the parameters
      have been configured, as we can't enable a manager with an incomplete
      configuration. Therefore, if a manager is disabled, don't check for the validity
      of it's parameters or the parameters of the overlays connected to it. Only check
      once it is enabled. Add a check in dss_check_settings_low() to achieve the same.
      
      Signed-off-by: default avatarArchit Taneja <archit@ti.com>
      5dd747e8