aboutsummaryrefslogtreecommitdiff
path: root/src/target/espressif/segger_sysview.h
diff options
context:
space:
mode:
Diffstat (limited to 'src/target/espressif/segger_sysview.h')
-rw-r--r--src/target/espressif/segger_sysview.h79
1 files changed, 79 insertions, 0 deletions
diff --git a/src/target/espressif/segger_sysview.h b/src/target/espressif/segger_sysview.h
new file mode 100644
index 0000000..d149cab
--- /dev/null
+++ b/src/target/espressif/segger_sysview.h
@@ -0,0 +1,79 @@
+/* SPDX-License-Identifier: BSD-1-Clause */
+/* SPDX-FileCopyrightText: (c) 1995-2021 SEGGER Microcontroller GmbH. All rights reserved. */
+/* SPDX-FileContributor: 2023 Espressif Systems (Shanghai) CO LTD */
+
+/*
+* The contend below is extracted from files SEGGER_SYSVIEW.h and SEGGER_SYSVIEW_Int.h in:
+* https://www.segger.com/downloads/systemview/systemview_target_src
+* SystemView version: 3.42
+*/
+
+#ifndef OPENOCD_TARGET_SEGGER_SYSVIEW_H
+#define OPENOCD_TARGET_SEGGER_SYSVIEW_H
+
+#define SYSVIEW_EVTID_NOP 0 /* Dummy packet. */
+#define SYSVIEW_EVTID_OVERFLOW 1
+#define SYSVIEW_EVTID_ISR_ENTER 2
+#define SYSVIEW_EVTID_ISR_EXIT 3
+#define SYSVIEW_EVTID_TASK_START_EXEC 4
+#define SYSVIEW_EVTID_TASK_STOP_EXEC 5
+#define SYSVIEW_EVTID_TASK_START_READY 6
+#define SYSVIEW_EVTID_TASK_STOP_READY 7
+#define SYSVIEW_EVTID_TASK_CREATE 8
+#define SYSVIEW_EVTID_TASK_INFO 9
+#define SYSVIEW_EVTID_TRACE_START 10
+#define SYSVIEW_EVTID_TRACE_STOP 11
+#define SYSVIEW_EVTID_SYSTIME_CYCLES 12
+#define SYSVIEW_EVTID_SYSTIME_US 13
+#define SYSVIEW_EVTID_SYSDESC 14
+#define SYSVIEW_EVTID_USER_START 15
+#define SYSVIEW_EVTID_USER_STOP 16
+#define SYSVIEW_EVTID_IDLE 17
+#define SYSVIEW_EVTID_ISR_TO_SCHEDULER 18
+#define SYSVIEW_EVTID_TIMER_ENTER 19
+#define SYSVIEW_EVTID_TIMER_EXIT 20
+#define SYSVIEW_EVTID_STACK_INFO 21
+#define SYSVIEW_EVTID_MODULEDESC 22
+
+#define SYSVIEW_EVTID_INIT 24
+#define SYSVIEW_EVTID_NAME_RESOURCE 25
+#define SYSVIEW_EVTID_PRINT_FORMATTED 26
+#define SYSVIEW_EVTID_NUMMODULES 27
+#define SYSVIEW_EVTID_END_CALL 28
+#define SYSVIEW_EVTID_TASK_TERMINATE 29
+
+#define SYSVIEW_EVTID_EX 31
+//
+// SystemView extended events. Sent with ID 31.
+//
+#define SYSVIEW_EVTID_EX_MARK 0
+#define SYSVIEW_EVTID_EX_NAME_MARKER 1
+#define SYSVIEW_EVTID_EX_HEAP_DEFINE 2
+#define SYSVIEW_EVTID_EX_HEAP_ALLOC 3
+#define SYSVIEW_EVTID_EX_HEAP_ALLOC_EX 4
+#define SYSVIEW_EVTID_EX_HEAP_FREE 5
+
+#define SYSVIEW_SYNC_LEN 10
+
+#define SYSVIEW_EVENT_ID_MAX (200)
+
+//
+// Commands that Host can send to target
+//
+enum {
+ SEGGER_SYSVIEW_COMMAND_ID_START = 1,
+ SEGGER_SYSVIEW_COMMAND_ID_STOP,
+ SEGGER_SYSVIEW_COMMAND_ID_GET_SYSTIME,
+ SEGGER_SYSVIEW_COMMAND_ID_GET_TASKLIST,
+ SEGGER_SYSVIEW_COMMAND_ID_GET_SYSDESC,
+ SEGGER_SYSVIEW_COMMAND_ID_GET_NUMMODULES,
+ SEGGER_SYSVIEW_COMMAND_ID_GET_MODULEDESC,
+ SEGGER_SYSVIEW_COMMAND_ID_HEARTBEAT = 127,
+ // Extended commands: Commands >= 128 have a second parameter
+ SEGGER_SYSVIEW_COMMAND_ID_GET_MODULE = 128
+};
+
+/* Minimum compatible SEGGER SystemView tool version */
+#define SYSVIEW_MIN_VER_STRING "SEGGER SystemViewer V2.42"
+
+#endif