summaryrefslogtreecommitdiff
path: root/ArmPlatformPkg/Library/SP804TimerLib
diff options
context:
space:
mode:
authoroliviermartin <oliviermartin@6f19259b-4bc3-4df7-8a09-765794883524>2011-06-03 09:32:39 +0000
committeroliviermartin <oliviermartin@6f19259b-4bc3-4df7-8a09-765794883524>2011-06-03 09:32:39 +0000
commit23792dea0ca521e8696c7994e9cc6d04581f0b2c (patch)
treecd16c0d235bfa0bce9c957150ce883e325f55d10 /ArmPlatformPkg/Library/SP804TimerLib
parent9dcfb8e5c8edb262a8e941d119af553205d38b2e (diff)
downloadedk2-23792dea0ca521e8696c7994e9cc6d04581f0b2c.zip
edk2-23792dea0ca521e8696c7994e9cc6d04581f0b2c.tar.gz
edk2-23792dea0ca521e8696c7994e9cc6d04581f0b2c.tar.bz2
ArmPlatformPkg/SP804Timer: Remove the SP810 System Controller dependency
The SP804 drivers must not consider the presence of the SP810 System Controller on the platform. The SP810 was used to enable the SP804 Dual Timers on ArmVExpress. It is the role of the Platform specific driver to enable to the SP804 dual timers if required. The former SP810 initialization code has moved to ArmPlatformLib for ArmRealViewEb and ArmVersatileExpress. git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@11744 6f19259b-4bc3-4df7-8a09-765794883524
Diffstat (limited to 'ArmPlatformPkg/Library/SP804TimerLib')
-rw-r--r--ArmPlatformPkg/Library/SP804TimerLib/SP804TimerLib.c57
1 files changed, 25 insertions, 32 deletions
diff --git a/ArmPlatformPkg/Library/SP804TimerLib/SP804TimerLib.c b/ArmPlatformPkg/Library/SP804TimerLib/SP804TimerLib.c
index 18be580..96c43aa 100644
--- a/ArmPlatformPkg/Library/SP804TimerLib/SP804TimerLib.c
+++ b/ArmPlatformPkg/Library/SP804TimerLib/SP804TimerLib.c
@@ -30,38 +30,32 @@ TimerConstructor (
VOID
)
{
- // Check if Timer 2 is already initialized
- if (MmioRead32(SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG) & SP804_TIMER_CTRL_ENABLE) {
- return RETURN_SUCCESS;
- } else {
- // configure SP810 to use 1MHz clock and disable
- MmioAndThenOr32 (SP810_CTRL_BASE + SP810_SYS_CTRL_REG, ~SP810_SYS_CTRL_TIMER2_EN, SP810_SYS_CTRL_TIMER2_TIMCLK);
-
- // configure timer 2 for one shot operation, 32 bits, no prescaler, and interrupt disabled
- MmioOr32 (SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ONESHOT | SP804_TIMER_CTRL_32BIT | SP804_PRESCALE_DIV_1);
-
- // preload the timer count register
- MmioWrite32 (SP804_TIMER2_BASE + SP804_TIMER_LOAD_REG, 1);
+ // Check if Timer 2 is already initialized
+ if (MmioRead32(SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG) & SP804_TIMER_CTRL_ENABLE) {
+ return RETURN_SUCCESS;
+ } else {
+ // Configure timer 2 for one shot operation, 32 bits, no prescaler, and interrupt disabled
+ MmioOr32 (SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ONESHOT | SP804_TIMER_CTRL_32BIT | SP804_PRESCALE_DIV_1);
- // enable the timer
- MmioOr32 (SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ENABLE);
- }
+ // Preload the timer count register
+ MmioWrite32 (SP804_TIMER2_BASE + SP804_TIMER_LOAD_REG, 1);
- // Check if Timer 3 is already initialized
- if (MmioRead32(SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG) & SP804_TIMER_CTRL_ENABLE) {
- return RETURN_SUCCESS;
- } else {
- // configure SP810 to use 1MHz clock and disable
- MmioAndThenOr32 (SP810_CTRL_BASE + SP810_SYS_CTRL_REG, ~SP810_SYS_CTRL_TIMER3_EN, SP810_SYS_CTRL_TIMER3_TIMCLK);
+ // Enable the timer
+ MmioOr32 (SP804_TIMER2_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ENABLE);
+ }
- // configure timer 3 for free running operation, 32 bits, no prescaler, interrupt disabled
- MmioOr32 (SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_32BIT | SP804_PRESCALE_DIV_1);
+ // Check if Timer 3 is already initialized
+ if (MmioRead32(SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG) & SP804_TIMER_CTRL_ENABLE) {
+ return RETURN_SUCCESS;
+ } else {
+ // Configure timer 3 for free running operation, 32 bits, no prescaler, interrupt disabled
+ MmioOr32 (SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_32BIT | SP804_PRESCALE_DIV_1);
- // enable the timer
- MmioOr32 (SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ENABLE);
- }
+ // Enable the timer
+ MmioOr32 (SP804_TIMER3_BASE + SP804_TIMER_CONTROL_REG, SP804_TIMER_CTRL_ENABLE);
+ }
- return RETURN_SUCCESS;
+ return RETURN_SUCCESS;
}
/**
@@ -141,11 +135,10 @@ GetPerformanceCounter (
{
// Free running 64-bit/32-bit counter is needed here.
// Don't think we need this to boot, just to do performance profile
- // ASSERT (FALSE);
- UINT32 val = MmioRead32 (SP804_TIMER3_BASE + SP804_TIMER_CURRENT_REG);
- ASSERT(val > 0);
-
- return (UINT64)val;
+ UINT64 Value;
+ Value = MmioRead32 (SP804_TIMER3_BASE + SP804_TIMER_CURRENT_REG);
+ ASSERT(Value > 0);
+ return Value;
}