diff options
author | Dmitry Fomichev <dmitry.fomichev@wdc.com> | 2020-09-28 11:35:15 +0900 |
---|---|---|
committer | Klaus Jensen <k.jensen@samsung.com> | 2020-10-27 11:29:25 +0100 |
commit | b865cabf735be793789ad2c7eac97f47a1325966 (patch) | |
tree | 84ac848c732d0a339cb3f46a86b82443f32dfff8 | |
parent | dcd1496132704ca16fc857a40370a6b9209341ae (diff) | |
download | qemu-b865cabf735be793789ad2c7eac97f47a1325966.zip qemu-b865cabf735be793789ad2c7eac97f47a1325966.tar.gz qemu-b865cabf735be793789ad2c7eac97f47a1325966.tar.bz2 |
hw/block/nvme: report actual LBA data shift in LBAF
Calculate the data shift value to report based on the set value of
logical_block_size device property.
In the process, use a local variable to calculate the LBA format
index instead of the hardcoded value 0. This makes the code more
readable and it will make it easier to add support for multiple LBA
formats in the future.
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
-rw-r--r-- | hw/block/nvme-ns.c | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/hw/block/nvme-ns.c b/hw/block/nvme-ns.c index 2ba0263..31c80cd 100644 --- a/hw/block/nvme-ns.c +++ b/hw/block/nvme-ns.c @@ -31,12 +31,13 @@ static void nvme_ns_init(NvmeNamespace *ns) { NvmeIdNs *id_ns = &ns->id_ns; + int lba_index = NVME_ID_NS_FLBAS_INDEX(ns->id_ns.flbas); if (blk_get_flags(ns->blkconf.blk) & BDRV_O_UNMAP) { ns->id_ns.dlfeat = 0x9; } - id_ns->lbaf[0].ds = BDRV_SECTOR_BITS; + id_ns->lbaf[lba_index].ds = 31 - clz32(ns->blkconf.logical_block_size); id_ns->nsze = cpu_to_le64(nvme_ns_nlbas(ns)); |