1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
|
------------------------------------------------------------------------------
-- --
-- GNAT COMPILER COMPONENTS --
-- --
-- P A R . L O A D --
-- --
-- B o d y --
-- --
-- Copyright (C) 1992-2006, Free Software Foundation, Inc. --
-- --
-- GNAT is free software; you can redistribute it and/or modify it under --
-- terms of the GNU General Public License as published by the Free Soft- --
-- ware Foundation; either version 2, or (at your option) any later ver- --
-- sion. GNAT is distributed in the hope that it will be useful, but WITH- --
-- OUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY --
-- or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License --
-- for more details. You should have received a copy of the GNU General --
-- Public License distributed with GNAT; see file COPYING. If not, write --
-- to the Free Software Foundation, 51 Franklin Street, Fifth Floor, --
-- Boston, MA 02110-1301, USA. --
-- --
-- GNAT was originally developed by the GNAT team at New York University. --
-- Extensive contributions were provided by Ada Core Technologies Inc. --
-- --
------------------------------------------------------------------------------
-- The Par.Load procedure loads all units that are definitely required before
-- it makes any sense at all to proceed with semantic analysis, including
-- with'ed units, corresponding specs for bodies, parents of child specs,
-- and parents of subunits. All these units are loaded and pointers installed
-- in the tree as described in the spec of package Lib.
with Fname.UF; use Fname.UF;
with Lib.Load; use Lib.Load;
with Uname; use Uname;
with Osint; use Osint;
with Sinput.L; use Sinput.L;
with Stylesw; use Stylesw;
with Validsw; use Validsw;
with GNAT.Spelling_Checker; use GNAT.Spelling_Checker;
separate (Par)
procedure Load is
File_Name : File_Name_Type;
-- Name of file for current unit, derived from unit name
Cur_Unum : constant Unit_Number_Type := Current_Source_Unit;
-- Unit number of unit that we just finished parsing. Note that we need
-- to capture this, because Source_Unit will change as we parse new
-- source files in the multiple main source file case.
Curunit : constant Node_Id := Cunit (Cur_Unum);
-- Compilation unit node for current compilation unit
Loc : Source_Ptr := Sloc (Curunit);
-- Source location for compilation unit node
Save_Style_Check : Boolean;
Save_Style_Checks : Style_Check_Options;
-- Save style check so it can be restored later
Save_Validity_Check : Boolean;
Save_Validity_Checks : Validity_Check_Options;
-- Save validity check so it can be restored later
With_Cunit : Node_Id;
-- Compilation unit node for withed unit
Context_Node : Node_Id;
-- Next node in context items list
With_Node : Node_Id;
-- N_With_Clause node
Spec_Name : Unit_Name_Type;
-- Unit name of required spec
Body_Name : Unit_Name_Type;
-- Unit name of corresponding body
Unum : Unit_Number_Type;
-- Unit number of loaded unit
Limited_With_Found : Boolean := False;
-- Set True if a limited WITH is found, used to ???
function Same_File_Name_Except_For_Case
(Expected_File_Name : File_Name_Type;
Actual_File_Name : File_Name_Type) return Boolean;
-- Given an actual file name and an expected file name (the latter being
-- derived from the unit name), determine if they are the same except for
-- possibly different casing of letters.
------------------------------------
-- Same_File_Name_Except_For_Case --
------------------------------------
function Same_File_Name_Except_For_Case
(Expected_File_Name : File_Name_Type;
Actual_File_Name : File_Name_Type) return Boolean
is
begin
Get_Name_String (Actual_File_Name);
Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
declare
Lower_Case_Actual_File_Name : String (1 .. Name_Len);
begin
Lower_Case_Actual_File_Name := Name_Buffer (1 .. Name_Len);
Get_Name_String (Expected_File_Name);
Canonical_Case_File_Name (Name_Buffer (1 .. Name_Len));
return Lower_Case_Actual_File_Name = Name_Buffer (1 .. Name_Len);
end;
end Same_File_Name_Except_For_Case;
-- Start of processing for Load
begin
-- Don't do any loads if we already had a fatal error
if Fatal_Error (Cur_Unum) then
return;
end if;
Save_Style_Check_Options (Save_Style_Checks);
Save_Style_Check := Opt.Style_Check;
Save_Validity_Check_Options (Save_Validity_Checks);
Save_Validity_Check := Opt.Validity_Checks_On;
-- If main unit, set Main_Unit_Entity (this will get overwritten if
-- the main unit has a separate spec, that happens later on in Load)
if Cur_Unum = Main_Unit then
Main_Unit_Entity := Cunit_Entity (Main_Unit);
end if;
-- If we have no unit name, things are seriously messed up by previous
-- errors, and we should not try to continue compilation.
if Unit_Name (Cur_Unum) = No_Name then
raise Unrecoverable_Error;
end if;
-- Next step, make sure that the unit name matches the file name
-- and issue a warning message if not. We only output this for the
-- main unit, since for other units it is more serious and is
-- caught in a separate test below. We also inhibit the message in
-- multiple unit per file mode, because in this case the relation
-- between file name and unit name is broken.
File_Name :=
Get_File_Name
(Unit_Name (Cur_Unum),
Subunit => Nkind (Unit (Cunit (Cur_Unum))) = N_Subunit);
if Cur_Unum = Main_Unit
and then Multiple_Unit_Index = 0
and then File_Name /= Unit_File_Name (Cur_Unum)
and then (File_Names_Case_Sensitive
or not Same_File_Name_Except_For_Case
(File_Name, Unit_File_Name (Cur_Unum)))
then
Error_Msg_Name_1 := File_Name;
Error_Msg
("?file name does not match unit name, should be{", Sloc (Curunit));
end if;
-- For units other than the main unit, the expected unit name is set and
-- must be the same as the actual unit name, or we are in big trouble, and
-- abandon the compilation since there are situations where this really
-- gets us into bad trouble (e.g. some subunit situations).
if Cur_Unum /= Main_Unit
and then Expected_Unit (Cur_Unum) /= Unit_Name (Cur_Unum)
then
Loc := Error_Location (Cur_Unum);
Error_Msg_Name_1 := Unit_File_Name (Cur_Unum);
Get_Name_String (Error_Msg_Name_1);
-- Check for predefined file case
if Name_Len > 1
and then Name_Buffer (2) = '-'
and then (Name_Buffer (1) = 'a'
or else
Name_Buffer (1) = 's'
or else
Name_Buffer (1) = 'i'
or else
Name_Buffer (1) = 'g')
then
declare
Expect_Name : constant Name_Id := Expected_Unit (Cur_Unum);
Actual_Name : constant Name_Id := Unit_Name (Cur_Unum);
begin
Error_Msg_Name_1 := Expect_Name;
Error_Msg ("% is not a predefined library unit!", Loc);
-- In the predefined file case, we know the user did not
-- construct their own package, but we got the wrong one.
-- This means that the name supplied by the user crunched
-- to something we recognized, but then the file did not
-- contain the unit expected. Most likely this is due to
-- a misspelling, e.g.
-- with Ada.Calender;
-- This crunches to a-calend, which indeed contains the unit
-- Ada.Calendar, and we can diagnose the misspelling. This
-- is a simple heuristic, but it catches many common cases
-- of misspelling of predefined unit names without needing
-- a full list of them.
-- Before actually issinying the message, we will check that the
-- unit name is indeed a plausible misspelling of the one we got.
if Is_Bad_Spelling_Of
(Found => Get_Name_String (Expect_Name),
Expect => Get_Name_String (Actual_Name))
then
Error_Msg_Name_1 := Actual_Name;
Error_Msg ("possible misspelling of %!", Loc);
end if;
end;
-- Non-predefined file name case. In this case we generate a message
-- and then we quit, because we are in big trouble, and if we try
-- to continue compilation, we get into some nasty situations
-- (for example in some subunit cases).
else
Error_Msg ("file { does not contain expected unit!", Loc);
Error_Msg_Unit_1 := Expected_Unit (Cur_Unum);
Error_Msg ("\\expected unit $!", Loc);
Error_Msg_Unit_1 := Unit_Name (Cur_Unum);
Error_Msg ("\\found unit $!", Loc);
end if;
-- In both cases, remove the unit if it is the last unit (which it
-- normally (always?) will be) so that it is out of the way later.
Remove_Unit (Cur_Unum);
end if;
-- If current unit is a body, load its corresponding spec
if Nkind (Unit (Curunit)) = N_Package_Body
or else Nkind (Unit (Curunit)) = N_Subprogram_Body
then
Spec_Name := Get_Spec_Name (Unit_Name (Cur_Unum));
Unum :=
Load_Unit
(Load_Name => Spec_Name,
Required => False,
Subunit => False,
Error_Node => Curunit,
Corr_Body => Cur_Unum);
-- If we successfully load the unit, then set the spec pointer. Once
-- again note that if the loaded unit has a fatal error, Load will
-- have set our Fatal_Error flag to propagate this condition.
if Unum /= No_Unit then
Set_Library_Unit (Curunit, Cunit (Unum));
-- If this is a separate spec for the main unit, then we reset
-- Main_Unit_Entity to point to the entity for this separate spec
if Cur_Unum = Main_Unit then
Main_Unit_Entity := Cunit_Entity (Unum);
end if;
-- If we don't find the spec, then if we have a subprogram body, we
-- are still OK, we just have a case of a body acting as its own spec
elsif Nkind (Unit (Curunit)) = N_Subprogram_Body then
Set_Acts_As_Spec (Curunit, True);
Set_Library_Unit (Curunit, Curunit);
-- Otherwise we do have an error, repeat the load request for the spec
-- with Required set True to generate an appropriate error message.
else
Unum :=
Load_Unit
(Load_Name => Spec_Name,
Required => True,
Subunit => False,
Error_Node => Curunit);
return;
end if;
-- If current unit is a child unit spec, load its parent. If the child unit
-- is loaded through a limited with, the parent must be as well.
elsif Nkind (Unit (Curunit)) = N_Package_Declaration
or else Nkind (Unit (Curunit)) = N_Subprogram_Declaration
or else Nkind (Unit (Curunit)) in N_Generic_Declaration
or else Nkind (Unit (Curunit)) in N_Generic_Instantiation
or else Nkind (Unit (Curunit)) in N_Renaming_Declaration
then
-- Turn style and validity checks off for parent unit
if not GNAT_Mode then
Reset_Style_Check_Options;
Reset_Validity_Check_Options;
end if;
Spec_Name := Get_Parent_Spec_Name (Unit_Name (Cur_Unum));
if Spec_Name /= No_Name then
Unum :=
Load_Unit
(Load_Name => Spec_Name,
Required => True,
Subunit => False,
Error_Node => Curunit,
From_Limited_With => From_Limited_With);
if Unum /= No_Unit then
Set_Parent_Spec (Unit (Curunit), Cunit (Unum));
end if;
end if;
-- If current unit is a subunit, then load its parent body
elsif Nkind (Unit (Curunit)) = N_Subunit then
Body_Name := Get_Parent_Body_Name (Unit_Name (Cur_Unum));
Unum :=
Load_Unit
(Load_Name => Body_Name,
Required => True,
Subunit => True,
Error_Node => Name (Unit (Curunit)));
if Unum /= No_Unit then
Set_Library_Unit (Curunit, Cunit (Unum));
end if;
end if;
-- Now we load with'ed units, with style/validity checks turned off
if not GNAT_Mode then
Reset_Style_Check_Options;
Reset_Validity_Check_Options;
end if;
-- Load the context items in two rounds: the first round handles normal
-- withed units and the second round handles Ada 2005 limited-withed units.
-- This is required to allow the low-level circuitry that detects circular
-- dependencies of units the correct notification of the following error:
-- limited with D;
-- with D; with C;
-- package C is ... package D is ...
for Round in 1 .. 2 loop
Context_Node := First (Context_Items (Curunit));
while Present (Context_Node) loop
-- During the first round we check if there is some limited-with
-- context clause; otherwise the second round will be skipped
if Nkind (Context_Node) = N_With_Clause
and then Round = 1
and then Limited_Present (Context_Node)
then
Limited_With_Found := True;
end if;
if Nkind (Context_Node) = N_With_Clause
and then ((Round = 1 and then not Limited_Present (Context_Node))
or else
(Round = 2 and then Limited_Present (Context_Node)))
then
With_Node := Context_Node;
Spec_Name := Get_Unit_Name (With_Node);
Unum :=
Load_Unit
(Load_Name => Spec_Name,
Required => False,
Subunit => False,
Error_Node => With_Node,
Renamings => True,
From_Limited_With => From_Limited_With
or else
Limited_Present (Context_Node));
-- If we find the unit, then set spec pointer in the N_With_Clause
-- to point to the compilation unit for the spec. Remember that
-- the Load routine itself sets our Fatal_Error flag if the loaded
-- unit gets a fatal error, so we don't need to worry about that.
if Unum /= No_Unit then
Set_Library_Unit (With_Node, Cunit (Unum));
-- If the spec isn't found, then try finding the corresponding
-- body, since it is possible that we have a subprogram body
-- that is acting as a spec (since no spec is present).
else
Body_Name := Get_Body_Name (Spec_Name);
Unum :=
Load_Unit
(Load_Name => Body_Name,
Required => False,
Subunit => False,
Error_Node => With_Node,
Renamings => True);
-- If we got a subprogram body, then mark that we are using
-- the body as a spec in the file table, and set the spec
-- pointer in the N_With_Clause to point to the body entity.
if Unum /= No_Unit
and then Nkind (Unit (Cunit (Unum))) = N_Subprogram_Body
then
With_Cunit := Cunit (Unum);
Set_Library_Unit (With_Node, With_Cunit);
Set_Acts_As_Spec (With_Cunit, True);
Set_Library_Unit (With_Cunit, With_Cunit);
-- If we couldn't find the body, or if it wasn't a body spec
-- then we are in trouble. We make one more call to Load to
-- require the spec. We know it will fail of course, the
-- purpose is to generate the required error message (we prefer
-- that this message refer to the missing spec, not the body)
else
Unum :=
Load_Unit
(Load_Name => Spec_Name,
Required => True,
Subunit => False,
Error_Node => With_Node,
Renamings => True);
-- Here we create a dummy package unit for the missing unit
Unum := Create_Dummy_Package_Unit (With_Node, Spec_Name);
Set_Library_Unit (With_Node, Cunit (Unum));
end if;
end if;
end if;
Next (Context_Node);
end loop;
exit when not Limited_With_Found;
end loop;
-- Restore style/validity check mode for main unit
Set_Style_Check_Options (Save_Style_Checks);
Opt.Style_Check := Save_Style_Check;
Set_Validity_Check_Options (Save_Validity_Checks);
Opt.Validity_Checks_On := Save_Validity_Check;
end Load;
|