rs6000: Fix sanitizer frame unwind on 32-bit ABIs
This fixes more than half of our testcase failures on BE. libsanitizer/ * sanitizer_common/sanitizer_stacktrace.cc (BufferedStackTrace::FastUnwindStack): Use the correct frame offset for PowerPC SYSV ABI. From-SVN: r258525
Diffstat (limited to 'libsanitizer')
-rw-r--r--libsanitizer/ChangeLog6
-rw-r--r--libsanitizer/sanitizer_common/sanitizer_stacktrace.cc13
2 files changed, 16 insertions, 3 deletions
diff --git a/libsanitizer/ChangeLog b/libsanitizer/ChangeLog
index b625083..f98188a 100644
--- a/libsanitizer/ChangeLog
+++ b/libsanitizer/ChangeLog
@@ -1,3 +1,9 @@
+2018-03-14 Segher Boessenkool <segher@kernel.crashing.org>
+
+ * sanitizer_common/sanitizer_stacktrace.cc
+ (BufferedStackTrace::FastUnwindStack): Use the correct frame offset
+ for PowerPC SYSV ABI.
+
2018-02-14 Igor Tsimbalist <igor.v.tsimbalist@intel.com>
PR target/84148
diff --git a/libsanitizer/sanitizer_common/sanitizer_stacktrace.cc b/libsanitizer/sanitizer_common/sanitizer_stacktrace.cc
index 83309d6..2de585c 100644
--- a/libsanitizer/sanitizer_common/sanitizer_stacktrace.cc
+++ b/libsanitizer/sanitizer_common/sanitizer_stacktrace.cc
@@ -78,14 +78,21 @@ void BufferedStackTrace::FastUnwindStack(uptr pc, uptr bp, uptr stack_top,
IsAligned((uptr)frame, sizeof(*frame)) &&
size < max_depth) {
#ifdef __powerpc__
- // PowerPC ABIs specify that the return address is saved at offset
- // 16 of the *caller's* stack frame. Thus we must dereference the
- // back chain to find the caller frame before extracting it.
+ // PowerPC ABIs specify that the return address is saved on the
+ // *caller's* stack frame. Thus we must dereference the back chain
+ // to find the caller frame before extracting it.
uhwptr *caller_frame = (uhwptr*)frame[0];
if (!IsValidFrame((uptr)caller_frame, stack_top, bottom) ||
!IsAligned((uptr)caller_frame, sizeof(uhwptr)))
break;
+ // For most ABIs the offset where the return address is saved is two
+ // register sizes. The exception is the SVR4 ABI, which uses an
+ // offset of only one register size.
+#ifdef _CALL_SYSV
+ uhwptr pc1 = caller_frame[1];
+#else
uhwptr pc1 = caller_frame[2];
+#endif
#elif defined(__s390__)
uhwptr pc1 = frame[14];
#else