When controlling an industrial radio modem it can be necessary to
manipulate the handshake lines in order to control the radio modem's
transmitter, from userspace.

The transmitter should not be turned off before all characters have been
transmitted.  serial8250_tx_empty() was reporting that all characters were
transmitted before they actually were.

===

Discovered in parallel with more testing and analysis by Kees Schoenmakers
as follows:

I ran into an NetMos 9835 serial pci board which behaves a little
different than the standard.  This type of expansion board is very common.

"Standard" 8250 compatible devices clear the 'UART_LST_TEMT" bit together
with the "UART_LSR_THRE" bit when writing data to the device.

The NetMos device does it slightly different

I believe that the TEMT bit is coupled to the shift register.  The problem
is that after writing data to the device and very quickly after that one
does call serial8250_tx_empty, it returns the w...