Fix unsymbolized stack history printing.
Summary: When symbols are unavailable, the current code prints sp: ... pc: ... (null) (null) instead of module name + offset. Change the output to include module name and offset, and also to match the regular sanitizer stack trace format so that it is recognized by symbolize.py out of the box. Reviewers: kcc, pcc Subscribers: kubamracek, jdoerfert, llvm-commits Tags: #llvm Differential Revision: https://reviews.llvm.org/D58267 llvm-svn: 354157