drm/amdkfd: AIP mGPUs best prefetch location for xnack on



For xnack on, if range ACCESS or ACCESS_IN_PLACE (AIP) by single GPU, or
range is ACCESS_IN_PLACE by mGPUs and all mGPUs connection on XGMI same
hive, the best prefetch location is prefetch_loc GPU. Otherwise, the best
prefetch location is always CPU because GPU does not have coherent
mapping VRAM of other GPUs even with large-BAR PCIe connection.

Signed-off-by: default avatarPhilip Yang <Philip.Yang@amd.com>
Reviewed-by: default avatarFelix Kuehling <Felix.Kuehling@amd.com>
Signed-off-by: default avatarAlex Deucher <alexander.deucher@amd.com>
parent f5bd5239
Loading
Loading
Loading
Loading
+19 −16
Original line number Diff line number Diff line
@@ -2675,22 +2675,26 @@ svm_range_add(struct kfd_process *p, uint64_t start, uint64_t size,
	return 0;
}

/* svm_range_best_prefetch_location - decide the best prefetch location
/**
 * svm_range_best_prefetch_location - decide the best prefetch location
 * @prange: svm range structure
 *
 * For xnack off:
 * If range map to single GPU, the best acutal location is prefetch loc, which
 * If range map to single GPU, the best prefetch location is prefetch_loc, which
 * can be CPU or GPU.
 *
 * If range map to multiple GPUs, only if mGPU connection on xgmi same hive,
 * the best actual location could be prefetch_loc GPU. If mGPU connection on
 * PCIe, the best actual location is always CPU, because GPU cannot access vram
 * of other GPUs, assuming PCIe small bar (large bar support is not upstream).
 * If range is ACCESS or ACCESS_IN_PLACE by mGPUs, only if mGPU connection on
 * XGMI same hive, the best prefetch location is prefetch_loc GPU, othervise
 * the best prefetch location is always CPU, because GPU can not have coherent
 * mapping VRAM of other GPUs even with large-BAR PCIe connection.
 *
 * For xnack on:
 * The best actual location is prefetch location. If mGPU connection on xgmi
 * same hive, range map to multiple GPUs. Otherwise, the range only map to
 * actual location GPU. Other GPU access vm fault will trigger migration.
 * If range is not ACCESS_IN_PLACE by mGPUs, the best prefetch location is
 * prefetch_loc, other GPU access will generate vm fault and trigger migration.
 *
 * If range is ACCESS_IN_PLACE by mGPUs, only if mGPU connection on XGMI same
 * hive, the best prefetch location is prefetch_loc GPU, otherwise the best
 * prefetch location is always CPU.
 *
 * Context: Process context
 *
@@ -2710,11 +2714,6 @@ svm_range_best_prefetch_location(struct svm_range *prange)

	p = container_of(prange->svms, struct kfd_process, svms);

	/* xnack on */
	if (p->xnack_enabled)
		goto out;

	/* xnack off */
	if (!best_loc || best_loc == KFD_IOCTL_SVM_LOCATION_UNDEFINED)
		goto out;

@@ -2724,6 +2723,10 @@ svm_range_best_prefetch_location(struct svm_range *prange)
		best_loc = 0;
		goto out;
	}

	if (p->xnack_enabled)
		bitmap_copy(bitmap, prange->bitmap_aip, MAX_GPU_INSTANCE);
	else
		bitmap_or(bitmap, prange->bitmap_access, prange->bitmap_aip,
			  MAX_GPU_INSTANCE);