Commit d0413118 authored by Luca Ceresoli's avatar Luca Ceresoli Committed by Rob Herring
Browse files

docs: dt: remove stale property-units.txt, link to current schema



property-units.txt is not maintained anymore. New suffixes are now
supported that have not been added here.

To avoid people incorrectly think a given suffix is not in the list remove
the file entirely and point to the authoritative place where the
recommended suffixes are maintained.

Signed-off-by: default avatarLuca Ceresoli <luca@lucaceresoli.net>
Link: https://lore.kernel.org/r/20210512152311.7399-1-luca@lucaceresoli.net


Signed-off-by: default avatarRob Herring <robh@kernel.org>
parent d1dd2167
Loading
Loading
Loading
Loading
+0 −48
Original line number Diff line number Diff line
Standard Unit Suffixes for Property names

Properties which have a unit of measure are recommended to have a unit
suffix appended to the property name. The list below contains the
recommended suffixes. Other variations exist in bindings, but should not
be used in new bindings or added here. The inconsistency in the unit
prefixes is due to selecting the most commonly used variants.

It is also recommended to use the units listed here and not add additional
unit prefixes.

Time/Frequency
----------------------------------------
-mhz		: megahertz
-hz		: hertz (preferred)
-sec		: second
-ms		: millisecond
-us		: microsecond
-ns		: nanosecond
-ps		: picosecond

Distance
----------------------------------------
-mm		: millimeter

Electricity
----------------------------------------
-microamp	: microampere
-microamp-hours : microampere hour
-ohms		: ohm
-micro-ohms	: microohm
-microwatt-hours: microwatt hour
-microvolt	: microvolt
-picofarads	: picofarad
-femtofarads	: femtofarad

Temperature
----------------------------------------
-celsius	: degree Celsius
-millicelsius	: millidegree Celsius

Pressure
----------------------------------------
-kpascal	: kilopascal

Throughput
----------------------------------------
-kBps		: kilobytes per second
+2 −1
Original line number Diff line number Diff line
@@ -52,7 +52,8 @@ Properties
  constraints specific to the device.

- DO use common property unit suffixes for properties with scientific units.
  See property-units.txt.
  Recommended suffixes are listed at
  https://github.com/devicetree-org/dt-schema/blob/master/schemas/property-units.yaml

- DO define properties in terms of constraints. How many entries? What are
  possible values? What is the order?