Loading Documentation/hwmon/ibmpowernv +19 −12 Original line number Diff line number Diff line Loading @@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV ======================== Supported systems: * Any recent IBM P servers based on POWERNV platform Author: Neelesh Gupta Loading Loading @@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. Sysfs attributes ---------------- ======================= ======================================================= fanX_input Measured RPM value. fanX_min Threshold RPM for alert generation. fanX_fault 0: No fail condition 1: Failing fan fanX_fault - 0: No fail condition - 1: Failing fan tempX_input Measured ambient temperature. tempX_max Threshold ambient temperature for alert generation. Loading @@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its temperature sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable inX_input Measured power supply voltage (millivolt) inX_fault 0: No fail condition. 1: Failing power supply. inX_fault - 0: No fail condition. - 1: Failing power supply. inX_highest Historical maximum voltage inX_lowest Historical minimum voltage inX_enable Enable/disable all voltage sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its voltage sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable powerX_input Power consumption (microWatt) powerX_input_highest Historical maximum power Loading @@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its power sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable currX_input Measured current (milliampere) currX_highest Historical maximum current Loading @@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its current sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable energyX_input Cumulative energy (microJoule) ======================= ======================================================= Loading
Documentation/hwmon/ibmpowernv +19 −12 Original line number Diff line number Diff line Loading @@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV ======================== Supported systems: * Any recent IBM P servers based on POWERNV platform Author: Neelesh Gupta Loading Loading @@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. Sysfs attributes ---------------- ======================= ======================================================= fanX_input Measured RPM value. fanX_min Threshold RPM for alert generation. fanX_fault 0: No fail condition 1: Failing fan fanX_fault - 0: No fail condition - 1: Failing fan tempX_input Measured ambient temperature. tempX_max Threshold ambient temperature for alert generation. Loading @@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its temperature sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable inX_input Measured power supply voltage (millivolt) inX_fault 0: No fail condition. 1: Failing power supply. inX_fault - 0: No fail condition. - 1: Failing power supply. inX_highest Historical maximum voltage inX_lowest Historical minimum voltage inX_enable Enable/disable all voltage sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its voltage sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable powerX_input Power consumption (microWatt) powerX_input_highest Historical maximum power Loading @@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its power sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable currX_input Measured current (milliampere) currX_highest Historical maximum current Loading @@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the sub-group. In POWER9, this attribute corresponds to each OCC. Using this attribute each OCC can be asked to disable/enable all of its current sensors. 1: Enable 0: Disable - 1: Enable - 0: Disable energyX_input Cumulative energy (microJoule) ======================= =======================================================