Commit 9d669336 authored by Andre Przywara's avatar Andre Przywara Committed by Florian Fainelli
Browse files

ARM: dts: Cygnus: Fix SP805 clocks



The SP805 DT binding requires two clocks to be specified, but the
Broadcom Cygnus DT currently only specifies one clock.

In practice, Linux would pick a clock named "apb_pclk" for the bus
clock, and the Linux and U-Boot SP805 driver would use the first clock
to derive the actual watchdog counter frequency.

Since currently both are the very same clock, we can just double the
clock reference, and add the correct clock-names, to match the binding.

Signed-off-by: default avatarAndre Przywara <andre.przywara@arm.com>
Reviewed-by: default avatarRay Jui <ray.jui@broadcom.com>
Acked-by: default avatarFlorian Fainelli <f.fainelli@gmail.com>
Signed-off-by: default avatarFlorian Fainelli <f.fainelli@gmail.com>
parent 5d00306e
Loading
Loading
Loading
Loading
+2 −2
Original line number Diff line number Diff line
@@ -234,8 +234,8 @@ wdt0: wdt@18009000 {
			compatible = "arm,sp805" , "arm,primecell";
			reg = <0x18009000 0x1000>;
			interrupts = <GIC_SPI 91 IRQ_TYPE_LEVEL_HIGH>;
			clocks = <&axi81_clk>;
			clock-names = "apb_pclk";
			clocks = <&axi81_clk>, <&axi81_clk>;
			clock-names = "wdog_clk", "apb_pclk";
		};

		gpio_ccm: gpio@1800a000 {