aboutsummaryrefslogtreecommitdiff
path: root/src
AgeCommit message (Collapse)AuthorFilesLines
2019-05-14helper/command: remove search for "ocd_" prefixAntonio Borneo1-8/+4
We do not register commands with special "ocd_" prefix anymore. Change-Id: I588816eb22c2435a97be5fbfa87ee5584274b02f Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5087 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14helper/command: remove command "command type"Paul Fertser1-35/+0
Once the wrapper "ocd_bouncer" is removed (which was the only user of this command), there is no reason to keep the command any longer. Remove it. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I979ce1c147babedb44dd77418751133f589f827c Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5084 Tested-by: jenkins
2019-05-14helper/command: do not replace new commands with ocd_ prefixPaul Fertser2-48/+2
The TCL return values are now consistent, no need anymore for the hack of registering the commands with "ocd_" prefix and override them with proc ocd_bouncer. Clean-up the command registration and remove the proc ocd_bouncer. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I2a467e73ecb068686ea3fda91bf961aba6db6427 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5086 Tested-by: jenkins
2019-05-14helper/command: do not capture log in script_command_run()Paul Fertser1-11/+3
Command's output should be put in JimTcl result. We should not anymore capture the log output and pack it as a JimTcl result. Remove the log capture feature in script_command_run(). This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Id326c8719e1cee9156d7fc15ae8355ec79a74951 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5085 Tested-by: jenkins
2019-05-14helper/command: Handle Tcl return values consistentlyPaul Fertser2-4/+12
Rationale: 1. There's logging output and there're return values; 2. If a function should return something, it should do it explicitly, same for logging; 3. Interactive interfaces (telnet, Gdb and Tcl RPC) must always return the result of the evaluation for the given expression. You can suppress this output by adding ``; after 0'' to the end of your expression. 4. Some commands "throw an exception" and if you want to be able to collect both the return value (when it succeeds) and the log output (when something goes wrong) you can use do like this: set log_output [capture "catch {reset_config} return_value"] So what I'm proposing is following: 1. Every jim_handler command should set the return value the standard JimTcl way, without any tricks. If it needs to print some logging output, it should use LOG_* functions. 2. The usual commands (COMMANDS) can easily construct their return value by appending strings with command_print() and command_print_sameline(). This required changing "struct command_invocation" and passing a pointer to it to command_print* functions. The code is already functional, please test and comment. TODO items: 1. Modify all jim_handler commands to properly return or log values (some of them are commented out for now in this patch). 2. Properly document "capture" command and provide a convenience function to automate log_output + return_value gathering. 3. Add appropriate Doxygen comments. 4. Add Tcl RPC interface description to the manual, all the example clients in different languages (from the mailing list) to contrib/. This change is the core part of http://openocd.zylin.com/1815 from Paul Fertser. It has been extracted and rebased to simplify the review and provided again as 1815. Change-Id: I675c91aa9da1e4e7c6f0a8fe6112a00550b9e4db Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/1815 Tested-by: jenkins
2019-05-14flash/nor: use command_print() in command "flash banks"Paul Fertser1-1/+1
The command uses LOG_USER() instead of command_print(). Fix it. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I92e5e5954a75b96093b3ed6af73a7536c063b639 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5083 Tested-by: jenkins
2019-05-14nor/niietcm4: fix indentationPaul Fertser1-9/+9
After replace CMD_CTX with CMD, the indentation is incorrect. Fix it. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I5d7c40227ceda2e9db8dab88088d74012d2254c4 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5082 Tested-by: jenkins
2019-05-14helper/command: change prototype of command_print/command_print_samelineAntonio Borneo104-962/+962
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should switch to CMD as first parameter. Change prototype of command_print() and command_print_sameline() to pass CMD instead of CMD_CTX. Since the first parameter is currently not used, the change can be done though scripts without manual coding. This patch is created using the command: sed -i PATTERN $(find src/ doc/ -type f) with all the following patters: 's/\(command_print(cmd\)->ctx,/\1,/' 's/\(command_print(CMD\)_CTX,/\1,/' 's/\(command_print(struct command_\)context \*context,/\1invocation *cmd,/' 's/\(command_print_sameline(cmd\)->ctx,/\1,/' 's/\(command_print_sameline(CMD\)_CTX,/\1,/' 's/\(command_print_sameline(struct command_\)context \*context,/\1invocation *cmd,/' This change is inspired by http://openocd.zylin.com/1815 from Paul Fertser but is now done through scripting. Change-Id: I3386d8f96cdc477e7a2308dd18269de3bed04385 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Signed-off-by: Paul Fertser <fercerpav@gmail.com> Reviewed-on: http://openocd.zylin.com/5081 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14jlink: change prototype of show_config*() functionsPaul Fertser1-25/+25
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of show_config*() functions to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I131a904774bf60ad1bf9d90dbc65927c246ac23a Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5080 Tested-by: jenkins
2019-05-14target/esirisc_trace: change prototype of trace dump functionsPaul Fertser1-14/+14
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of esirisc_trace_dump*() functions to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ia43bff112372cbb76e1aea9f59f4a9b6df05c15d Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5079 Tested-by: jenkins Reviewed-by: Steven Stallion <sstallion@gmail.com>
2019-05-14target/esirisc_trace: change prototype of trace analyse functionsPaul Fertser1-36/+36
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of esirisc_trace_analyze*() functions to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ie7cfd323fe591a987ea648a20be2bb9c7273dde8 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5078 Tested-by: jenkins Reviewed-by: Steven Stallion <sstallion@gmail.com>
2019-05-14target: change prototype of binprint()Paul Fertser1-8/+8
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of binprint() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I5ebdc50417d97c791c98ac0cfe2218319809eb7f Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5077 Tested-by: jenkins
2019-05-14target: change prototype of handle_bp_command_set()Paul Fertser1-9/+9
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of handle_bp_command_set() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: If00f9cfb784b53bb3df92d4469178e2f930a146a Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5076 Tested-by: jenkins
2019-05-14target: change prototype of handle_bp_command_list()Paul Fertser1-8/+8
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of handle_bp_command_list() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ibff636d476bcd59784ce3da5409d930225cfe637 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5075 Tested-by: jenkins
2019-05-14target: change prototype of handle_md_output()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of handle_md_output() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I2150201fad3fd3bc0be89249dcbd314b38a6f860 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5074 Tested-by: jenkins
2019-05-14target/arm_adi_v5: change prototype of dap_rom_display()Paul Fertser3-34/+34
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of dap_rom_display() and dap_info_command() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Idb97b20759c03fcecbac1184c354966f469caa5f Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5073 Tested-by: jenkins
2019-05-14target/etm: change prototype of etmv1_analyze_trace()Paul Fertser1-14/+14
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of etmv1_analyze_trace() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ic923af5480a54c7272d2ff1abbe235ba941cf1a0 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5072 Tested-by: jenkins
2019-05-14target/x86_32_common: change prototype of handle_iod_output()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of handle_iod_output() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I67f594c80d6bbbbf6c9567069a545f16877b1e94 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5071 Tested-by: jenkins
2019-05-14target/armv7a_cache_l2x: change prototype of ↵Paul Fertser1-4/+4
arm7a_handle_l2x_cache_info_command() To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm7a_handle_l2x_cache_info_command() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ib926cd7380ac8b6fb89f64e0a85d81d124633315 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5070 Tested-by: jenkins
2019-05-14target/armv7a: change prototype of armv7a_handle_cache_info_command()Paul Fertser4-8/+8
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of armv7a_handle_cache_info_command() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I27f507869cb41c74722a759e69dfd45658fcd4be Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5069 Tested-by: jenkins
2019-05-14target/armv4_5_cache: change prototype of armv4_5_handle_cache_info_command()Paul Fertser5-10/+10
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of armv4_5_handle_cache_info_command() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ib6ab3ec2fc6504c2a0635b654697a4b6e12a3750 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5068 Tested-by: jenkins
2019-05-14target/dsp563xx: change prototype of handle_md_output()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of handle_md_output() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ib0b84c933689ac8c940c9bbe62d9c95fd015c4f5 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5067 Tested-by: jenkins
2019-05-14target/armv8: change prototype of display_cache_info()Paul Fertser4-10/+10
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of display_cache_info(), armv8_handle_inner_cache_info_command() and armv8_handle_cache_info_command() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I13519c79af82cdba57d5205ba84a5a27fce65a36 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5066 Tested-by: jenkins
2019-05-14target/xscale: change prototype of xscale_display_instruction()Paul Fertser1-11/+11
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of xscale_display_instruction() and of xscale_analyze_trace() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I8420f19c1b2ff0d2a2f2a8d3627767f7acda437c Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5065 Tested-by: jenkins
2019-05-14target/xscale: change prototype of xscale_verify_pointer()Paul Fertser1-14/+14
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of xscale_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Id047fab41ec4f673a46756b0ab901e659e088544 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5064 Tested-by: jenkins
2019-05-14target/mips_m4k: change prototype of mips_m4k_verify_pointer()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of mips_m4k_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I9fa3e883d2ca9cc858caaefd33586f78638702f5 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5063 Tested-by: jenkins
2019-05-14target/mips32: change prototype of mips32_verify_pointer()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of mips32_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ic4a4de10518ee009d6df420e7278fd028e1f22ca Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5062 Tested-by: jenkins
2019-05-14target/cortex_m: change prototype of cortex_m_verify_pointer()Paul Fertser1-5/+5
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of cortex_m_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Icf6d1e5f8b4a3ce115c4253e49769df19a5211ae Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5061 Tested-by: jenkins
2019-05-14target/arm946e: change prototype of arm946e_verify_pointer()Paul Fertser1-4/+4
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm946e_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ib7119e2b009d05eec47b50c3b9d32feaebc97538 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5060 Tested-by: jenkins
2019-05-14target/arm720t: change prototype of arm720t_verify_pointer()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm720t_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I7fa0628fabacd9ceb62ce921192f88edca659c15 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5059 Tested-by: jenkins
2019-05-14target/arm966e: change prototype of arm966e_verify_pointer()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm966e_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I92745591256ad56a588b6386842028e0b18dec96 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5058 Tested-by: jenkins
2019-05-14target/arm926ejs: change prototype of arm926ejs_verify_pointer()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm926ejs_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ibbb03429a7fe8b9979f9bb9e513f9eb86aee3b5b Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5057 Tested-by: jenkins
2019-05-14target/arm920t: change prototype of arm920t_verify_pointer()Paul Fertser1-7/+7
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of arm920t_verify_pointer() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I9a603d7c032df91b3913aadb242de89dbed0358e Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5056 Tested-by: jenkins
2019-05-14nor/at91sam4: change prototype of get_current_sam4()Paul Fertser1-8/+8
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of get_current_sam4() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I8dfa66f3f6be318d6ba89649279b1b4502f375d9 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5055 Tested-by: jenkins
2019-05-14nor/at91sam3: change prototype of get_current_sam3()Paul Fertser1-8/+8
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of get_current_sam3() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ia1e7af79d0fc89d229b4e10df37317a374bbab62 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5054 Tested-by: jenkins
2019-05-14nand/tcl: pass CMD to nand_list_walker()Paul Fertser1-3/+3
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Pass CMD instead of CMD_CTX as parameter to nand_list_walker(). This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: Ia11887dfc6dc58d5458a88ba84780cd895b8c253 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5053 Tested-by: jenkins
2019-05-14nand/fileio: change prototype of nand_fileio_start()Paul Fertser3-6/+6
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of nand_fileio_start() to pass CMD instead of CMD_CTX. This change was part of http://openocd.zylin.com/1815 from Paul Fertser and has been extracted and rebased to simplify the review. Change-Id: I7993f6aba997a2d2917949563651c8d0c213730d Signed-off-by: Paul Fertser <fercerpav@gmail.com> Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5052 Tested-by: jenkins
2019-05-14target_request: replace command_print() with command_output_text()Antonio Borneo1-2/+2
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. When dumping traces or semihosting text, the command that enabled it is already completed, so CMD is not a valid value. Plus, we want the dump to be printed in the command context where the enable command was executed. Replace command_print() with command_output_text(). Change-Id: I297a2b799a914233499641062407cf6e8b9fe012 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5051 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14target: unify memory read/write commandsAntonio Borneo1-231/+23
Current code provides two independent implementations for the memory read/write commands: a) jim_target_md()/jim_target_mw() for the target specific commands "<target> m[dw][bhw]" b) handle_md_command()/handle_mw_command() for the current target commands "m[dw][bhwd]" The case a) misses the handling of doubleword and calls functions command_print_sameline() with first parameter NULL because defined as jim handler. Remove the code in jim_target_md()/jim_target_mw() and use the same code in b) for the target specific memory read/write. This approach also provides support for 64-bit data size, not present in the implementation in a). The only drawback is that the implementation of memory read in b) prints the data also as human readable ASCII characters, feature missing in the implementation in a). This could introduced later if it's really needed. Update the documentation to: - add 64-bit support - add phys parameter - add the count parameter Add attribute "unused" to target_buffer_get_u8(), now not used anymore. Change-Id: Ib11ff924c409ad87e77fe708d628b2cc82b74d6a Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5050 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14target: use LOG_USER to print errors in eventsAntonio Borneo1-1/+6
Events are supposed to be executed asynchronously and not linked with any command, so it's incorrect printing out an eventual error using command_print(). Even in the case of events triggered by the command <target> invoke-event <event-name> the eventual error in the event handler is not propagated to the command, so the command_print() is still not appropriate. Replace command_print() with LOG_USER() in target_handle_event(). Add further info in the log to identify which event has generated the error and its associated target. Before return, clean-up the error message and the stacktrace from the error already displayed, to avoid propagate them. Change-Id: I5966aa25e7c81348f4ad4d6e7ce5d4dee44ea4c8 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5049 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14target: change prototype of target_process_reset()Antonio Borneo1-5/+5
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should be ready to switch to CMD as first parameter. Change prototype of target_process_reset() to pass CMD instead of CMD_CTX. Replace NULL parameter of command_print(). Remove extra newline, already added by command_print(). Change-Id: Ieb820c2586e1ff74a0c2b63a9c8693ca7710dfb7 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5048 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14helper/command: add macro CMDAntonio Borneo1-0/+5
Accessing the variable "cmd" in a COMMAND_HANDLER is confusing because the variable definition is not visible in the prototype, thus "cmd" can be identified by the reader as a global variable defined somewhere else. Add the new macro CMD to make more evident it is a part of the COMMAND_HANDLER. Change-Id: I8f63da593a931045cc404323f143b88c5c80ab5e Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5047 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-14target/arm946e: rewrite jim_arm946e_cp15 to arm945e_handle_cp15Tomas Vanek1-38/+22
jim_arm946e_cp15() used command_print() in the jim handler. Change-Id: I0a258aad5a60f45672b9b6fa6819691507d4f0f6 Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5000 Tested-by: jenkins
2019-05-14target: rewrite jim_target_event_list to handle_target_event_listTomas Vanek1-12/+11
jim_target_event_list handler used command_print() in jim handler. Rewriting the jim handler to the OpenOCD command is easy as get_current_target() returns proper target for prefixed commands since bb9d9c60264a905926e0d15f84842858d0de80b7 Change-Id: I3e937249386ca5dbd7a5dd6ebb0ccde0911325d8 Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/4993 Tested-by: jenkins
2019-05-04stm32h7x: fix incorrect indentationChristopher Head1-8/+8
Change-Id: I5dc16031c38576d853774b6123c93be1e1b4aa96 Signed-off-by: Christopher Head <chead@zaber.com> Reviewed-on: http://openocd.zylin.com/5133 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-04flash/nor/stm32h7x: use of wait queue flag instead of the busy flagTarek BOCHKATI1-18/+19
Based on RM0433.rev5 > Section 3.3.9 : Flash program operations: QW1/2: this bit indicates that a write, erase or option byte change operation is pending in the write queue or command queue buffer. It remains high until the write operation is complete. It supersedes the BSY1/2 status bit. On this basis, stm32x_wait_status_busy is renamed accordingly to be 'stm32x_wait_flash_op_queue' Note : In this commit there is a fix of SR_ERROR_MASK value in flash loader algo Note : This modification is mandatory for revision X, and backward compatible with old revisions Change-Id: I59d2973317d76b01fbb0fb5e4a472a47d0a7a5b5 Signed-off-by: Laurent LEMELE <laurent.lemele@st.com> Signed-off-by: Tarek BOCHKATI <tarek.bouchkati@gmail.com> Reviewed-on: http://openocd.zylin.com/4883 Tested-by: jenkins Reviewed-by: Christopher Head <chead@zaber.com> Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-05-04flash/nor/atsame5: fix typo in dsu_reset_deassert help textTomas Vanek1-1/+1
Change-Id: Iebed1a160376717d19c5f56b2553f7d4d1eed3a7 Signed-off-by: Tomas Vanek <vanekt@fbl.cz> Reviewed-on: http://openocd.zylin.com/5095 Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com> Tested-by: jenkins
2019-04-24flash/fespi: Use COMMAND_PARSE_ADDRESSTim Newsome1-3/+1
Signed-off-by: Tim Newsome <tim@sifive.com> Change-Id: If4d22fe1440f926271274820f96428718a127ac2 Reviewed-on: http://openocd.zylin.com/5100 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
2019-04-24armv7a: Improve parsing of MPIDR register to avoid error message for Cortex R5Tommy Vestermark2-13/+16
References: - ARM DDI0406C ARMv7 Architecture Reference Manual, section B4.1.106 - ARM DDI0460D Cortex-R5 Technical Reference Manual section 4.3.6 - ARM 100048_0002_0 Cortex-A73 Technical Reference Manual section 4.5.2 Tested on: TMS570LC4357 Change-Id: Ie0d45fb697697f78cc4ad4e7a0116be9772590ba Signed-off-by: Tommy Vestermark <tov@vestermark.dk> Reviewed-on: http://openocd.zylin.com/5108 Tested-by: jenkins Reviewed-by: Matthias Welwarsky <matthias@welwarsky.de>
2019-04-24target/cortex_a: use extensively cortex_a_wait_dscr_bits()Antonio Borneo1-71/+39
We have the function to wait for bits in dscr. Use it whenever possible. When the bit to test is DSCR_INSTR_COMP, use instead the wrapper function cortex_a_wait_instrcmpl(). Change-Id: I5c54c239a00f489712af448eb97752210b4b38b8 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/5113 Tested-by: jenkins Reviewed-by: Matthias Welwarsky <matthias@welwarsky.de>