.. _OPAL_SIGNAL_SYSTEM_RESET: OPAL_SIGNAL_SYSTEM_RESET ======================== :: int64_t signal_system_reset(int32_t cpu_nr); This OPAL call causes the specified cpu(s) to be reset to the system reset exception handler (0x100). The exact contents of system registers (e.g., SRR1 wakeup causes) may vary depending on implementation and should not be relied upon. Resetting active threads on the same core as this call is run may not be supported by some platforms. In that case, OPAL_PARTIAL will be returned and NONE of the interrupts will be delivered. Arguments --------- :: int32_t cpu_nr cpu_nr >= 0 The cpu server number of the target cpu to reset. SYS_RESET_ALL (-1) All cpus should be reset. SYS_RESET_ALL_OTHERS (-2) All but the current cpu should be reset. Returns ------- OPAL_SUCCESS The power down was updated successful. OPAL_PARAMETER A parameter was incorrect. OPAL_HARDWARE Hardware indicated failure during reset. OPAL_PARTIAL Platform can not reset all requested CPUs at this time. This requires platform-specific code to work around, otherwise to be treated as failure. No CPUs are reset. OPAL_UNSUPPORTED This processor/platform is not supported.