From 325073da2dfd88ca99602756ee834723f6dec5af Mon Sep 17 00:00:00 2001 From: Stewart Smith Date: Fri, 26 Aug 2016 14:32:18 +1000 Subject: Add skiboot-5.3.2 release notes Signed-off-by: Stewart Smith --- doc/release-notes/skiboot-5.3.2.txt | 28 ++++++++++++++++++++++++++++ 1 file changed, 28 insertions(+) create mode 100644 doc/release-notes/skiboot-5.3.2.txt diff --git a/doc/release-notes/skiboot-5.3.2.txt b/doc/release-notes/skiboot-5.3.2.txt new file mode 100644 index 0000000..e93c3cd --- /dev/null +++ b/doc/release-notes/skiboot-5.3.2.txt @@ -0,0 +1,28 @@ +skiboot-5.3.2 +------------- + +skiboot-5.3.2 was released on Friday August 26th, 2016. + +This is the 3rd stable release of skiboot 5.3, the new stable release of +skiboot (first released with 5.3.0 on August 2nd, 2016). + +Skiboot 5.3.2 replaces skiboot-5.3.1 as the current stable version. It contains +a few minor bug fixes. + +Over skiboot-5.3.1, the following fixes are included: + +- opal/hmi: Fix a TOD HMI failure during a race condition. + Rare race condition which meant we wouldn't recover from TOD error + +- lpc: Log LPC SYNC errors as unrecoverable ones for manufacturing + Only affects systems in manufacturing mode. + No behaviour change when not in manufacturing mode. + +- hw/phb3: Update capi initialization sequence + The capi initialization sequence was revised in a circumvention + document when a 'link down' error was converted from fatal to Endpoint + Recoverable. Other, non-capi, register setup was corrected even before + the initial open-source release of skiboot, but a few capi-related + registers were not updated then, so this patch fixes it. + The point is that a link-down error detected by the UTL logic will + lead to an AIB fence, so that the CAPP unit can detect the error. -- cgit v1.1