diff options
author | Stewart Smith <stewart@linux.vnet.ibm.com> | 2016-01-27 16:00:15 +1100 |
---|---|---|
committer | Stewart Smith <stewart@linux.vnet.ibm.com> | 2016-01-27 16:00:15 +1100 |
commit | e3f129efba356a83f05e5932510efd8b157730ad (patch) | |
tree | 52bde18564ba36f95924a5f7a4c6ccb5ec398fba | |
parent | daa14bab184c5c85c04e4aedac129e2e09d7c879 (diff) | |
parent | 0671bb857f442efde618f1968c30e2b4828c6924 (diff) | |
download | skiboot-e3f129efba356a83f05e5932510efd8b157730ad.zip skiboot-e3f129efba356a83f05e5932510efd8b157730ad.tar.gz skiboot-e3f129efba356a83f05e5932510efd8b157730ad.tar.bz2 |
Merge skiboot-5.1.13 release notes
-rw-r--r-- | doc/release-notes/skiboot-5.1.13.txt | 43 |
1 files changed, 43 insertions, 0 deletions
diff --git a/doc/release-notes/skiboot-5.1.13.txt b/doc/release-notes/skiboot-5.1.13.txt new file mode 100644 index 0000000..0bc3100 --- /dev/null +++ b/doc/release-notes/skiboot-5.1.13.txt @@ -0,0 +1,43 @@ +skiboot-5.1.13 +-------------- + +skiboot-5.1.13 was released on Wed January 27th, 2016. + +skiboot-5.1.13 is the 14th stable release of 5.1, it follows skiboot-5.1.12 +(which was released December 4th, 2015). This release contains bug fixes. + +General: +- core/device.c: Sort nodes with name@unit names by unit + - This gives predictable device tree ordering to the payload + (usually petitboot) + - This means that utilities such as "lspci" will always return the same + ordering. +- Add OPAL_CONSOLE_FLUSH to the OPAL API + uart consoles only flush output when polled. The Linux kernel calls + these pollers frequently, except when in a panic state. As such, panic + messages are not fully printed unless the system is configured to reboot + after panic. + + This patch adds a new call to the OPAL API to flush the buffer. If the + system has a uart console (i.e. BMC machines), it will incrementally + flush the buffer, returning if there is more to be flushed or not. If + the system has a different console, the function will have no effect. + This will allow the Linux kernel to ensure that panic message have been + fully printed out. + +CAPI: +- hmi: Identify the phb upon CAPI malfunction alert + Previously, any error on a CAPI adapter would assume PHB0. + This could cause issues on Firestone machines. + +gard utility: +- Fix displaying 'cleared' gard records + When a garded component is replaced hostboot detects this and updates the + gard partition. + + Previously, there was ambiguity on if the gard record ID or the whole gard + record needed to be erased. This fix makes gard and hostboot agree. + +firestone platform: +- fix spacing in slot name + The other SlotN names have no space. |