diff options
author | John Preston <johnprestonmail@gmail.com> | 2018-11-28 18:22:28 +0400 |
---|---|---|
committer | Jussi Pakkanen <jpakkane@gmail.com> | 2018-12-04 20:19:19 +0200 |
commit | c17a80f47b772d759aeb0878aa767a768a6fdd0c (patch) | |
tree | 568b959bd2023617f38752fe33d506cc99a62366 /mesonbuild/backend/vs2010backend.py | |
parent | 8612f1543f280342fcbff69863b8401319fccc7d (diff) | |
download | meson-c17a80f47b772d759aeb0878aa767a768a6fdd0c.zip meson-c17a80f47b772d759aeb0878aa767a768a6fdd0c.tar.gz meson-c17a80f47b772d759aeb0878aa767a768a6fdd0c.tar.bz2 |
Use correct environment for REGEN in VS backend.
Try to guess which VS Command Prompt was used for the Meson call.
If one is chosen invoke it before calling Meson in REGEN command.
Diffstat (limited to 'mesonbuild/backend/vs2010backend.py')
-rw-r--r-- | mesonbuild/backend/vs2010backend.py | 33 |
1 files changed, 31 insertions, 2 deletions
diff --git a/mesonbuild/backend/vs2010backend.py b/mesonbuild/backend/vs2010backend.py index ea52f12..f9f7b93 100644 --- a/mesonbuild/backend/vs2010backend.py +++ b/mesonbuild/backend/vs2010backend.py @@ -189,6 +189,33 @@ class Vs2010Backend(backends.Backend): with open(filename, 'wb') as f: pickle.dump(regeninfo, f) + def get_vcvars_command(self): + has_arch_values = 'VSCMD_ARG_TGT_ARCH' in os.environ and 'VSCMD_ARG_HOST_ARCH' in os.environ + + # Use vcvarsall.bat if we found it. + if 'VCINSTALLDIR' in os.environ: + vs_version = os.environ['VisualStudioVersion'] \ + if 'VisualStudioVersion' in os.environ else None + relative_path = 'Auxiliary\\Build\\' if vs_version == '15.0' else '' + script_path = os.environ['VCINSTALLDIR'] + relative_path + 'vcvarsall.bat' + if os.path.exists(script_path): + if has_arch_values: + target_arch = os.environ['VSCMD_ARG_TGT_ARCH'] + host_arch = os.environ['VSCMD_ARG_HOST_ARCH'] + else: + target_arch = os.environ.get('Platform', 'x86') + host_arch = target_arch + arch = host_arch + '_' + target_arch if host_arch != target_arch else target_arch + return '"%s" %s' % (script_path, arch) + + # Otherwise try the VS2017 Developer Command Prompt. + if 'VS150COMNTOOLS' in os.environ and has_arch_values: + script_path = os.environ['VS150COMNTOOLS'] + 'VsDevCmd.bat' + if os.path.exists(script_path): + return '"%s" -arch=%s -host_arch=%s' % \ + (script_path, os.environ['VSCMD_ARG_TGT_ARCH'], os.environ['VSCMD_ARG_HOST_ARCH']) + return '' + def get_obj_target_deps(self, obj_list): result = {} for o in obj_list: @@ -1096,7 +1123,7 @@ class Vs2010Backend(backends.Backend): elif targetplatform == 'arm': targetmachine.text = 'MachineARM' else: - raise MesonException('Unsupported Visual Studio target machine: ' + targetmachine) + raise MesonException('Unsupported Visual Studio target machine: ' + targetplatform) meson_file_group = ET.SubElement(root, 'ItemGroup') ET.SubElement(meson_file_group, 'None', Include=os.path.join(proj_to_src_dir, build_filename)) @@ -1213,7 +1240,9 @@ class Vs2010Backend(backends.Backend): ET.SubElement(midl, 'ProxyFileName').text = '%(Filename)_p.c' regen_command = self.environment.get_build_command() + ['--internal', 'regencheck'] private_dir = self.environment.get_scratch_dir() + vcvars_command = self.get_vcvars_command() cmd_templ = '''setlocal +call %s > NUL "%s" "%s" if %%errorlevel%% neq 0 goto :cmEnd :cmEnd @@ -1231,7 +1260,7 @@ if %%errorlevel%% neq 0 goto :VCEnd''' message = ET.SubElement(custombuild, 'Message') message.text = 'Checking whether solution needs to be regenerated.' ET.SubElement(custombuild, 'Command').text = cmd_templ % \ - ('" "'.join(regen_command), private_dir) + (vcvars_command, '" "'.join(regen_command), private_dir) ET.SubElement(custombuild, 'Outputs').text = Vs2010Backend.get_regen_stampfile(self.environment.get_build_dir()) deps = self.get_regen_filelist() ET.SubElement(custombuild, 'AdditionalInputs').text = ';'.join(deps) |