diff options
author | Niklas Cassel <niklas.cassel@wdc.com> | 2023-06-09 16:08:40 +0200 |
---|---|---|
committer | John Snow <jsnow@redhat.com> | 2023-09-06 22:48:04 -0400 |
commit | e2a5d9b3d9c3d311618160603cc9bc04fbd98796 (patch) | |
tree | 46af87e256875076608db95d9c10195ffa672c0f /hw | |
parent | 2967dc8209dd27b61a6ab7bad78cf7c6ec58ddb4 (diff) | |
download | qemu-e2a5d9b3d9c3d311618160603cc9bc04fbd98796.zip qemu-e2a5d9b3d9c3d311618160603cc9bc04fbd98796.tar.gz qemu-e2a5d9b3d9c3d311618160603cc9bc04fbd98796.tar.bz2 |
hw/ide/ahci: simplify and document PxCI handling
The AHCI spec states that:
For NCQ, PxCI is cleared on command queued successfully.
For non-NCQ, PxCI is cleared on command completed successfully.
(A non-NCQ command that completes with error does not clear PxCI.)
The current QEMU implementation either clears PxCI in check_cmd(),
or in ahci_cmd_done().
check_cmd() will clear PxCI for a command if handle_cmd() returns 0.
handle_cmd() will return -1 if BUSY or DRQ is set.
The QEMU implementation for NCQ commands will currently not set BUSY
or DRQ, so they will always have PxCI cleared by handle_cmd().
ahci_cmd_done() will never even get called for NCQ commands.
Non-NCQ commands are executed by ide_bus_exec_cmd().
Non-NCQ commands in QEMU are implemented either in a sync or in an async
way.
For non-NCQ commands implemented in a sync way, the command handler will
return true, and when ide_bus_exec_cmd() sees that a command handler
returns true, it will call ide_cmd_done() (which will call
ahci_cmd_done()). For a command implemented in a sync way,
ahci_cmd_done() will do nothing (since busy_slot is not set). Instead,
after ide_bus_exec_cmd() has finished, check_cmd() will clear PxCI for
these commands.
For non-NCQ commands implemented in an async way (using either aiocb or
pio_aiocb), the command handler will return false, ide_bus_exec_cmd()
will not call ide_cmd_done(), instead it is expected that the async
callback function will call ide_cmd_done() once the async command is
done. handle_cmd() will set busy_slot, if and only if BUSY or DRQ is
set, and this is checked _after_ ide_bus_exec_cmd() has returned.
handle_cmd() will return -1, so check_cmd() will not clear PxCI.
When the async callback calls ide_cmd_done() (which will call
ahci_cmd_done()), it will see that busy_slot is set, and
ahci_cmd_done() will clear PxCI.
This seems racy, since busy_slot is set _after_ ide_bus_exec_cmd() has
returned. The callback might come before busy_slot gets set. And it is
quite confusing that ahci_cmd_done() will be called for all non-NCQ
commands when the command is done, but will only clear PxCI in certain
cases, even though it will always write a D2H FIS and raise an IRQ.
Even worse, in the case where ahci_cmd_done() does not clear PxCI, it
still raises an IRQ. Host software might thus read an old PxCI value,
since PxCI is cleared (by check_cmd()) after the IRQ has been raised.
Try to simplify this by always setting busy_slot for non-NCQ commands,
such that ahci_cmd_done() will always be responsible for clearing PxCI
for non-NCQ commands.
For NCQ commands, clear PxCI when we receive the D2H FIS, but before
raising the IRQ, see AHCI 1.3.1, section 5.3.8, states RegFIS:Entry and
RegFIS:ClearCI.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Message-id: 20230609140844.202795-5-nks@flawful.org
Signed-off-by: John Snow <jsnow@redhat.com>
Diffstat (limited to 'hw')
-rw-r--r-- | hw/ide/ahci.c | 70 |
1 files changed, 50 insertions, 20 deletions
diff --git a/hw/ide/ahci.c b/hw/ide/ahci.c index 4b27239..3deaf01 100644 --- a/hw/ide/ahci.c +++ b/hw/ide/ahci.c @@ -41,9 +41,10 @@ #include "trace.h" static void check_cmd(AHCIState *s, int port); -static int handle_cmd(AHCIState *s, int port, uint8_t slot); +static void handle_cmd(AHCIState *s, int port, uint8_t slot); static void ahci_reset_port(AHCIState *s, int port); static bool ahci_write_fis_d2h(AHCIDevice *ad, bool d2h_fis_i); +static void ahci_clear_cmd_issue(AHCIDevice *ad, uint8_t slot); static void ahci_init_d2h(AHCIDevice *ad); static int ahci_dma_prepare_buf(const IDEDMA *dma, int32_t limit); static bool ahci_map_clb_address(AHCIDevice *ad); @@ -591,9 +592,8 @@ static void check_cmd(AHCIState *s, int port) if ((pr->cmd & PORT_CMD_START) && pr->cmd_issue) { for (slot = 0; (slot < 32) && pr->cmd_issue; slot++) { - if ((pr->cmd_issue & (1U << slot)) && - !handle_cmd(s, port, slot)) { - pr->cmd_issue &= ~(1U << slot); + if (pr->cmd_issue & (1U << slot)) { + handle_cmd(s, port, slot); } } } @@ -1123,6 +1123,22 @@ static void process_ncq_command(AHCIState *s, int port, const uint8_t *cmd_fis, return; } + /* + * A NCQ command clears the bit in PxCI after the command has been QUEUED + * successfully (ERROR not set, BUSY and DRQ cleared). + * + * For NCQ commands, PxCI will always be cleared here. + * + * (Once the NCQ command is COMPLETED, the device will send a SDB FIS with + * the interrupt bit set, which will clear PxSACT and raise an interrupt.) + */ + ahci_clear_cmd_issue(ad, slot); + + /* + * In reality, for NCQ commands, PxCI is cleared after receiving a D2H FIS + * without the interrupt bit set, but since ahci_write_fis_d2h() can raise + * an IRQ on error, we need to call them in reverse order. + */ ahci_write_fis_d2h(ad, false); ncq_tfs->used = 1; @@ -1197,6 +1213,7 @@ static void handle_reg_h2d_fis(AHCIState *s, int port, { IDEState *ide_state = &s->dev[port].port.ifs[0]; AHCICmdHdr *cmd = get_cmd_header(s, port, slot); + AHCIDevice *ad = &s->dev[port]; uint16_t opts = le16_to_cpu(cmd->opts); if (cmd_fis[1] & 0x0F) { @@ -1273,11 +1290,19 @@ static void handle_reg_h2d_fis(AHCIState *s, int port, /* Reset transferred byte counter */ cmd->status = 0; + /* + * A non-NCQ command clears the bit in PxCI after the command has COMPLETED + * successfully (ERROR not set, BUSY and DRQ cleared). + * + * For non-NCQ commands, PxCI will always be cleared by ahci_cmd_done(). + */ + ad->busy_slot = slot; + /* We're ready to process the command in FIS byte 2. */ ide_bus_exec_cmd(&s->dev[port].port, cmd_fis[2]); } -static int handle_cmd(AHCIState *s, int port, uint8_t slot) +static void handle_cmd(AHCIState *s, int port, uint8_t slot) { IDEState *ide_state; uint64_t tbl_addr; @@ -1288,12 +1313,12 @@ static int handle_cmd(AHCIState *s, int port, uint8_t slot) if (s->dev[port].port.ifs[0].status & (BUSY_STAT|DRQ_STAT)) { /* Engine currently busy, try again later */ trace_handle_cmd_busy(s, port); - return -1; + return; } if (!s->dev[port].lst) { trace_handle_cmd_nolist(s, port); - return -1; + return; } cmd = get_cmd_header(s, port, slot); /* remember current slot handle for later */ @@ -1303,7 +1328,7 @@ static int handle_cmd(AHCIState *s, int port, uint8_t slot) ide_state = &s->dev[port].port.ifs[0]; if (!ide_state->blk) { trace_handle_cmd_badport(s, port); - return -1; + return; } tbl_addr = le64_to_cpu(cmd->tbl_addr); @@ -1312,7 +1337,7 @@ static int handle_cmd(AHCIState *s, int port, uint8_t slot) DMA_DIRECTION_TO_DEVICE, MEMTXATTRS_UNSPECIFIED); if (!cmd_fis) { trace_handle_cmd_badfis(s, port); - return -1; + return; } else if (cmd_len != 0x80) { ahci_trigger_irq(s, &s->dev[port], AHCI_PORT_IRQ_BIT_HBFS); trace_handle_cmd_badmap(s, port, cmd_len); @@ -1336,15 +1361,6 @@ static int handle_cmd(AHCIState *s, int port, uint8_t slot) out: dma_memory_unmap(s->as, cmd_fis, cmd_len, DMA_DIRECTION_TO_DEVICE, cmd_len); - - if (s->dev[port].port.ifs[0].status & (BUSY_STAT|DRQ_STAT)) { - /* async command, complete later */ - s->dev[port].busy_slot = slot; - return -1; - } - - /* done handling the command */ - return 0; } /* Transfer PIO data between RAM and device */ @@ -1498,6 +1514,16 @@ static int ahci_dma_rw_buf(const IDEDMA *dma, bool is_write) return 1; } +static void ahci_clear_cmd_issue(AHCIDevice *ad, uint8_t slot) +{ + IDEState *ide_state = &ad->port.ifs[0]; + + if (!(ide_state->status & (BUSY_STAT | DRQ_STAT))) { + ad->port_regs.cmd_issue &= ~(1 << slot); + } +} + +/* Non-NCQ command is done - This function is never called for NCQ commands. */ static void ahci_cmd_done(const IDEDMA *dma) { AHCIDevice *ad = DO_UPCAST(AHCIDevice, dma, dma); @@ -1506,11 +1532,15 @@ static void ahci_cmd_done(const IDEDMA *dma) /* no longer busy */ if (ad->busy_slot != -1) { - ad->port_regs.cmd_issue &= ~(1 << ad->busy_slot); + ahci_clear_cmd_issue(ad, ad->busy_slot); ad->busy_slot = -1; } - /* update d2h status */ + /* + * In reality, for non-NCQ commands, PxCI is cleared after receiving a D2H + * FIS with the interrupt bit set, but since ahci_write_fis_d2h() will raise + * an IRQ, we need to call them in reverse order. + */ ahci_write_fis_d2h(ad, true); if (ad->port_regs.cmd_issue && !ad->check_bh) { |