1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
|
.\" Copyright (c) 1991, 1992 Free Software Foundation
.\" See section COPYING for conditions for redistribution
.TH gld 1 "23 January 1992" "cygnus support" "GNU Development Tools"
.de BP
.sp
.ti \-.2i
\(**
..
.SH NAME
gld \- the GNU linker
.SH SYNOPSIS
.hy 0
.na
.TP
.B gld
.RB "[\|" \-o "
.I output\c
\&\|] \c
.I objfiles\c
\&.\|.\|.
.br
.RB "[\|" \-A\c
.I architecture\c
\&\|]
.RB "[\|" "\-b\ "\c
.I input-format\c
\&\|]
.RB "[\|" \-Bstatic "\|]"
.RB "[\|" "\-c\ "\c
.I commandfile\c
\&\|]
.RB "[\|" \-d | \-dc | \-dp\c
\|]
.br
.RB "[\|" "\-defsym\ "\c
.I symbol\c
\& = \c
.I expression\c
\&\|]
.RB "[\|" "\-e\ "\c
.I entry\c
\&\|]
.RB "[\|" \-F "\|]"
.RB "[\|" "\-F\ "\c
.I format\c
\&\|]
.RB "[\|" "\-format\ "\c
.I input-format\c
\&\|]
.RB "[\|" \-g "\|]"
.RB "[\|" \-i "\|]"
.RB "[\|" \-l\c
.I ar\c
\&\|]
.RB "[\|" \-L\c
.I searchdir\c
\&\|]
.RB "[\|" \-M | \-m "\|]"
.RB "[\|" \-n "\|]"
.RB "[\|" \-noinhibit-exec "\|]"
.RB "[\|" "\-R\ "\c
.I filename\c
\&\|]
.RB "[\|" \-relax "\|]"
.RB "[\|" \-r | \-Ur "\|]"
.RB "[\|" \-S "\|]"
.RB "[\|" \-s "\|]"
.RB "[\|" "\-T\ "\c
.I commandfile\c
\&\|]
.RB "[\|" "\-Ttext\ "\c
.I textorg\c
\&\|]
.RB "[\|" "\-Tdata\ "\c
.I dataorg\c
\&\|]
.RB "[\|" "\-Tbss\ "\c
.I bssorg\c
\&\|]
.RB "[\|" \-t "\|]"
.RB "[\|" "\-u\ "\c
.I sym\c
\&]
.RB "[\|" \-v "\|]"
.RB "[\|" \-X "\|]"
.RB "[\|" \-x "\|]"
.RB "[\|" { \c
.I script\c
.BR } "\|]"
.ad b
.hy 1
.SH DESCRIPTION
\c
.B gld\c
\& combines a number of object and archive files, relocates
their data and ties up symbol references. Often the last step in
building a new compiled program to run is a call to \c
.B gld\c
\&.
\c
.B gld\c
\& accepts Linker Command Language files
to provide explicit and total control over the linking process.
This man page does not describe the command language; see the `\|\c
.B ld\c
\|' entry in `\|\c
.B info\c
\|', or the manual
.I
gld: the GNU linker
\&, for full details on the command language and on other aspects of
the GNU linker.
This version of \c
.B gld\c
\& uses the general purpose BFD libraries
to operate on object files. This allows \c
.B gld\c
\& to read, combine, and
write object files in many different formats\(em\&for example, COFF or
\c
.B a.out\c
\&. Different formats may be linked together to produce any
available kind of object file. You can use `\|\c
.B objdump \-i\c
\|' to get a list of formats supported on various architectures; see
.BR objdump ( 1 ).
Aside from its flexibility, the GNU linker is more helpful than other
linkers in providing diagnostic information. Many linkers abandon
execution immediately upon encountering an error; whenever possible,
\c
.B gld\c
\& continues executing, allowing you to identify other errors
(or, in some cases, to get an output file in spite of the error).
The GNU linker \c
.B gld\c
\& is meant to cover a broad range of situations,
and to be as compatible as possible with other linkers. As a result,
you have many choices to control its behavior through the command line,
and through environment variables.
.SH OPTIONS
The plethora of command-line options may seem intimidating, but in
actual practice few of them are used in any particular context.
For instance, a frequent use of \c
.B gld\c
\& is to link standard Unix
object files on a standard, supported Unix system. On such a system, to
link a file \c
.B hello.o\c
\&:
.sp
.br
$\ gld\ \-o\ output\ /lib/crt0.o\ hello.o\ \-lc
.br
.sp
This tells \c
.B gld\c
\& to produce a file called \c
.B output\c
\& as the
result of linking the file \c
.B /lib/crt0.o\c
\& with \c
.B hello.o\c
\& and
the library \c
.B libc.a\c
\& which will come from the standard search
directories.
The command-line options to \c
.B gld\c
\& may be specified in any order, and
may be repeated at will. For the most part, repeating an option with a
different argument will either have no further effect, or override prior
occurrences (those further to the left on the command line) of an
option.
The exceptions\(em\&which may meaningfully be used more than once\(em\&are
\c
.B \-A\c
\&, \c
.B \-b\c
\& (or its synonym \c
.B \-format\c
\&), \c
.B \-defsym\c
\&,
\c
.B \-L\c
\&, \c
.B \-l\c
\&, \c
.B \-R\c
\&, and \c
.B \-u\c
\&.
The list of object files to be linked together, shown as \c
.I objfiles\c
\&,
may follow, precede, or be mixed in with command-line options; save that
an \c
.I objfiles\c
\& argument may not be placed between an option flag and
its argument.
Usually the linker is invoked with at least one object file, but other
forms of binary input files can also be specified with \c
.B \-l\c
\&,
\c
.B \-R\c
\&, and the script command language. If \c
.I no\c
\& binary input
files at all are specified, the linker does not produce any output, and
issues the message `\|\c
.B No input files\c
\|'.
Option arguments must either follow the option letter without intervening
whitespace, or be given as separate arguments immediately following the
option that requires them.
.TP
.IR "objfiles" .\|.\|.
The object files \c
.I objfiles\c
\& to be linked.
.TP
.BI "-A" "architecture"\c
\&
In the current release of \c
.B gld\c
\&, this option is useful only for the
Intel 960 family of architectures. In that \c
.B gld\c
\& configuration, the
\c
.I architecture\c
\& argument is one of the two-letter names identifying
members of the 960 family; the option specifies the desired output
target, and warns of any incompatible instructions in the input files.
It also modifies the linker's search strategy for archive libraries, to
support the use of libraries specific to each particular
architecture, by including in the search loop names suffixed with the
string identifying the architecture.
For example, if your \c
.B gld\c
\& command line included `\|\c
.B \-ACA\c
\|' as
well as `\|\c
.B \-ltry\c
\|', the linker would look (in its built-in search
paths, and in any paths you specify with \c
.B \-L\c
\&) for a library with
the names
.sp
.br
try
.br
libtry.a
.br
tryca
.br
libtryca.a
.br
.sp
The first two possibilities would be considered in any event; the last
two are due to the use of `\|\c
.B \-ACA\c
\|'.
Future releases of \c
.B gld\c
\& may support similar functionality for
other architecture families.
You can meaningfully use \c
.B \-A\c
\& more than once on a command line, if
an architecture family allows combination of target architectures; each
use will add another pair of name variants to search for when \c
.B \-l\c
\&
specifies a library.
.TP
.BI "-b " "input-format"\c
\&
Specify the binary format for input object files that follow this option
on the command line. You don't usually need to specify this, as
\c
.B gld\c
\& is configured to expect as a default input format the most
usual format on each machine. \c
.I input-format\c
\& is a text string, the
name of a particular format supported by the BFD libraries.
\c
.B \-format \c
.I input-format\c
\&\c
\& has the same effect.
You may want to use this option if you are linking files with an unusual
binary format. You can also use \c
.B \-b\c
\& to switch formats explicitly (when
linking object files of different formats), by including
\c
.B \-b \c
.I input-format\c
\&\c
\& before each group of object files in a
particular format.
The default format is taken from the environment variable
.B GNUTARGET\c
\&. You can also define the input
format from a script, using the command \c
.B TARGET\c
\&.
.TP
.B \-Bstatic
This flag is accepted for command-line compatibility with the SunOS linker,
but has no effect on \c
.B gld\c
\&.
.TP
.BI "-c " "commandfile"\c
\&
Directs \c
.B gld\c
\& to read link commands from the file
\c
.I commandfile\c
\&. These commands will completely override \c
.B gld\c
\&'s
default link format (rather than adding to it); \c
.I commandfile\c
\& must
specify everything necessary to describe the target format.
You may also include a script of link commands directly in the command
line by bracketing it between `\|\c
.B {\c
\|' and `\|\c
.B }\c
\|' characters.
.TP
.B \-d
.TP
.B \-dc
.TP
.B \-dp
These three options are equivalent; multiple forms are supported for
compatibility with other linkers. Use any of them to make \c
.B ld\c
\&
assign space to common symbols even if a relocatable output file is
specified (\c
.B \-r\c
\&). The script command
\c
.B FORCE_COMMON_ALLOCATION\c
\& has the same effect.
.TP
.BI "-defsym " "symbol"\c
\& = \c
.I expression\c
\&
Create a global symbol in the output file, containing the absolute
address given by \c
.I expression\c
\&. You may use this option as many
times as necessary to define multiple symbols in the command line. A
limited form of arithmetic is supported for the \c
.I expression\c
\& in this
context: you may give a hexadecimal constant or the name of an existing
symbol, or use \c
.B +\c
\& and \c
.B \-\c
\& to add or subtract hexadecimal
constants or symbols. If you need more elaborate expressions, consider
using the linker command language from a script.
.TP
.BI "-e " "entry"\c
\&
Use \c
.I entry\c
\& as the explicit symbol for beginning execution of your
program, rather than the default entry point. for a
discussion of defaults and other ways of specifying the
entry point.
.TP
.B \-F
.TP
.BI "-F" "format"\c
\&
Some older linkers used this option throughout a compilation toolchain
for specifying object-file format for both input and output object
files. \c
.B gld\c
\&'s mechanisms (the \c
.B \-b\c
\& or \c
.B \-format\c
\& options
for input files, the \c
.B TARGET\c
\& command in linker scripts for output
files, the \c
.B GNUTARGET\c
\& environment variable) are more flexible, but
but it accepts (and ignores) the \c
.B \-F\c
\& option flag for compatibility
with scripts written to call the old linker.
.TP
.BI "-format " "input-format"\c
\&
Synonym for \c
.B \-b\c
\& \c
.I input-format\c
\&.
.TP
.B \-g
Accepted, but ignored; provided for compatibility with other tools.
.TP
.B \-i
Perform an incremental link (same as option \c
.B \-r\c
\&).
.TP
.BI "-l" "ar"\c
\&
Add an archive file \c
.I ar\c
\& to the list of files to link. This
option may be used any number of times. \c
.B ld\c
\& will search its
path-list for occurrences of \c
.B lib\c
.I ar\c
\&.a\c
\& for every \c
.I ar\c
\&
specified.
.TP
.BI "-L" "searchdir"\c
\&
This command adds path \c
.I searchdir\c
\& to the list of paths that
\c
.B gld\c
\& will search for archive libraries. You may use this option
any number of times.
The default set of paths searched (without being specified with
\c
.B \-L\c
\&) depends on what emulation mode \c
.B gld\c
\& is using, and in
some cases also on how it was configured. The
paths can also be specified in a link script with the \c
.B SEARCH_DIR\c
\&
command.
.TP
.B \-M
.TP
.B \-m
Print (to the standard output file) a link map\(em\&diagnostic information
about where symbols are mapped by \c
.B ld\c
\&, and information on global
common storage allocation.
.TP
.B \-n
sets the text segment to be read only, and \c
.B NMAGIC\c
\& is written
if possible.
.TP
.B \-noinhibit-exec
Normally, the linker will not produce an output file if it encounters
errors during the link process. With this flag, you can specify that
you wish the output file retained even after non-fatal errors.
.TP
.BI "-o " "output"\c
\&
.I output\c
\&
\c
.I output\c
\& is a name for the program produced by \c
.B ld\c
\&; if this
option is not specified, the name `\|\c
.B a.out\c
\|' is used by default. The
script command \c
.B OUTPUT\c
\& can also specify the output file name.
.TP
.BI "-R " "filename"\c
\&
.I file\c
\&
Read symbol names and their addresses from \c
.I filename\c
\&, but do not
relocate it or include it in the output. This allows your output file
to refer symbolically to absolute locations of memory defined in other
programs.
.TP
.B \-relax
An option with machine dependent effects. Currently this option is only
supported on the H8/300.
On some platforms, use this option to perform global optimizations that
become possible when the linker resolves addressing in your program, such
as relaxing address modes and synthesizing new instructions in the
output object file.
On platforms where this is not supported, `\|\c
.B \-relax\c
\&\|' is accepted, but has no effect.
.TP
.B \-r
Generates relocatable output\(em\&i.e., generate an output file that can in
turn serve as input to \c
.B gld\c
\&. This is often called \c
.I partial
linking\c
\&. As a side effect, in environments that support standard Unix
magic numbers, this option also sets the output file's magic number to
\c
.B OMAGIC\c
\&.
If this option is not specified, an absolute file is produced. When
linking C++ programs, this option \c
.I will not\c
\& resolve references to
constructors; \c
.B \-Ur\c
\& is an alternative.
This option does the same as \c
.B \-i\c
\&.
.TP
.B \-S
Omits debugger symbol information (but not all symbols) from the output file.
.TP
.B \-s
Omits all symbol information from the output file.
.TP
.BI "{ " "script" " }"
You can, if you wish, include a script of linker commands directly in
the command line instead of referring to it via an input file. When the
character `\|\c
.B {\c
\|' occurs on the command line, the linker switches to
interpreting the command language until the end of the list of commands
is reached\(em\&flagged with a closing brace `\|\c
.B }\c
\|'. Other command-line
options will not be recognized while parsing the script.
for a description of the command language.
.TP
.BI "-Tbss " "org"\c
.TP
.BI "-Tdata " "org"\c
.TP
.BI "-Ttext " "org"\c
Use \c
.I org\c
\& as the starting address for\(em\&respectively\(em\&the
\c
.B bss\c
\&, \c
.B data\c
\&, or the \c
.B text\c
\& segment of the output file.
\c
.I textorg\c
\& must be a hexadecimal integer.
.TP
.BI "-T " "commandfile"\c
\&
.TP
.BI "-T" "commandfile"\c
Equivalent to \c
.B \-c \c
.I commandfile\c
\&\c
\&; supported for compatibility with
other tools.
.TP
.B \-t
Prints names of input files as \c
.B ld\c
\& processes them.
.TP
.BI "-u " "sym"\c
\&
.I sym\c
\&
Forces \c
.I sym\c
\& to be entered in the output file as an undefined symbol.
This may, for example, trigger linking of additional modules from
standard libraries. \c
.B \-u\c
\& may be repeated with different option
arguments to enter additional undefined symbols.
.TP
.B \-Ur
For anything other than C++ programs, this option is equivalent to
\c
.B \-r\c
\&: it generates relocatable output\(em\&i.e., an output file that can in
turn serve as input to \c
.B gld\c
\&. When linking C++ programs, \c
.B \-Ur\c
\&
\c
.I will\c
\& resolve references to constructors, unlike \c
.B \-r\c
\&.
.TP
.B \-v
Display the version number for \c
.B gld\c
\&.
.TP
.B \-X
If \c
.B \-s\c
\& or \c
.B \-S\c
\& is also specified, delete only local symbols
beginning with `\|\c
.B L\c
\|'.
.TP
.B \-x
If \c
.B \-s\c
\& or \c
.B \-S\c
\& is also specified, delete all local symbols,
not just those beginning with `\|\c
.B L\c
\|'.
.PP
.SH ENVIRONMENT
\c
.B gld\c
\& always consults two environment variables: \c
.B GNUTARGET\c
\&
and \c
.B LDEMULATION\c
\&. Depending on the setting of the latter, other
environment variables may be used as well.
\c
.B GNUTARGET\c
\& determines the input-file object format if you don't
use \c
.B \-b\c
\& (or its synonym \c
.B \-format\c
\&). Its value should be one
of the BFD names for an input format. If there is no
\c
.B GNUTARGET\c
\& in the environment, \c
.B gld\c
\& uses the natural format
of the host. If \c
.B GNUTARGET\c
\& is set to \c
.B default\c
\& then BFD attempts to discover the
input format by examining binary input files; this method often
succeeds, but there are potential ambiguities, since there is no method
of ensuring that the magic number used to flag object-file formats is
unique. However, the configuration procedure for BFD on each system
places the conventional format for that system first in the search-list,
so ambiguities are resolved in favor of convention.
\c
.B LDEMULATION\c
\& controls some aspects of \c
.B gld\c
\&'s dominant
personality. Although \c
.B gld\c
\& is flexible enough to permit its use
in many contexts regardless of configuration, you can use this variable
to make it act more like one or another older linker by default.
In particular, the value of \c
.B LDEMULATION\c
\& controls what default
linker script is used (thereby controlling the default input and output
formats; ; what default paths are searched for
archive libraries; and in some cases whether additional linker script
commands are available.
Here is the current set of emulations available:
.TP
.B LDEMULATION=gld
Emulate the older GNU linker. When this emulation is selected, the
default library search paths are
.sp
.br
/lib
.br
/usr/lib
.br
/usr/local/lib/lib
.br
.sp
The default output format is set to \c
.B a.out-generic-big\c
\&, and the
default machine is the system's configured BFD default.
.TP
.B LDEMULATION=gld68k
A variant of the \c
.B gld\c
\& emulation; only differs in specifically
setting the default BFD machine as \c
.B m68k\c
\&.
.TP
.B LDEMULATION=gld960
Emulate the Intel port of the older \c
.B gld\c
\& for the i960
architectures. The default library search paths are taken from two
other environment variables, \c
.B G960LIB\c
\& and \c
.B G960BASE\c
\&. The
default architecture is \c
.B i960\c
\&. The default output format is set
to \c
.B b.out.big\c
\&, and in fact the default output file name (if
\c
.B \-o\c
\& is not specified) is \c
.B b.out\c
\&, to reflect this variant
format, for this emulation.
This emulation can behave slightly differently depending on the setting
of the \c
.B gld\c
\& compile-time switch \c
.B GNU960\c
\&. If \c
.B gld\c
\& is
compiled with \c
.B GNU960\c
\& defined, then an additional environment
variable\(em\&\c
.B GNUTARGET\c
\&\(em\&is available; its value, if available,
specifies some other default output format than \c
.B b.out.big\c
\&.
.TP
.B LDEMULATION=gldm88kbcs
Sets the output format to \c
.B m88kbcs\c
\& and the architecture to
\c
.B m88k\c
\&. Default library search paths are
.sp
.br
/lib
.br
/usr/lib
.br
/usr/local/lib
.br
.sp
.TP
.B LDEMULATION=lnk960
Emulate the Intel linker \c
.B lnk960\c
\&. The default output format is
\c
.B coff-Intel-big\c
\&. With this emulation, \c
.B gld\c
\&
supports the additional script commands \c
.B HLL\c
\& and \c
.B SYSLIB\c
\& for
specification of library archives. This is the only emulation with
extensive support for the \c
.B \-A\c
\& (architecture) command-line option.
By default, the architecture \c
.B CORE\c
\& is assumed, but you can choose
additional features from the i960 architecture family by using one of
the following with \c
.B \-A\c
\& (or by using the \c
.B OUTPUT_ARCH\c
\& command
from a script):
.sp
.br
CORE
.br
KB
.br
SB
.br
MC
.br
XA
.br
CA
.br
KA
.br
SA
.br
.sp
The default libraries are chosen with some attention to the architecture
selected; the core library `\|\c
.B cg\c
\|' is always included, but the library
\c
.B fpg\c
\& is also used if you've specified any of the architectures
\c
.B KA\c
\&, \c
.B SA\c
\&, or \c
.B CA\c
\&.
Like \c
.B gld960\c
\&, this emulation uses additional environment variables
to set the default library search paths. Also like \c
.B gld960\c
\&, the
behavior of this emulation is slightly different depending on whether
\c
.B gld\c
\& itself was compiled with \c
.B GNU960\c
\& defined.
If your \c
.B gld\c
\& was compiled with \c
.B GNU960\c
\& defined, the default
paths are taken from all three of \c
.B G960LIB\c
\&, \c
.B G960BASE\c
\&, and
\c
.B I960BASE\c
\&. For the first two, paths you supply are automatically
suffixed with `\|\c
.B /lib/libcoff\c
\|'; for the last, your path is
automatically suffixed with `\|\c
.B /lib\c
\|'.
If your \c
.B gld\c
\& was \c
.I not\c
\& compiled with \c
.B GNU960\c
\& defined,
the default paths are taken from \c
.B I960BASE\c
\&, and \c
.B G960BASE\c
\& is
only consulted if \c
.B I960BASE\c
\& is undefined. In this case
\c
.B G960LIB\c
\& is not used at all.
.TP
.B LDEMULATION=vanilla
This is the least specific setting for \c
.B gld\c
\&. You can set
\c
.B LDEMULATION=vanilla\c
\& to disable emulation of other linkers. This
setting makes \c
.B gld\c
\& take the default machine from the BFD
configuration on your system; \c
.B a.out-generic-big\c
\& is the default
target. No other defaults are specified.
.PP
.SH "SEE ALSO"
.BR objdump ( 1 )
.br
.br
.RB "`\|" ld "\|' and `\|" binutils "\|'"
entries in
.B info\c
.br
.I
gld: the GNU linker\c
, Steve Chamberlain and Roland Pesch;
.I
The GNU Binary Utilities\c
, Roland H. Pesch.
.SH COPYING
Copyright (c) 1991, 1992 Free Software Foundation, Inc.
.PP
Permission is granted to make and distribute verbatim copies of
this manual provided the copyright notice and this permission notice
are preserved on all copies.
.PP
Permission is granted to copy and distribute modified versions of this
manual under the conditions for verbatim copying, provided that the
entire resulting derived work is distributed under the terms of a
permission notice identical to this one.
.PP
Permission is granted to copy and distribute translations of this
manual into another language, under the above conditions for modified
versions, except that this permission notice may be included in
translations approved by the Free Software Foundation instead of in
the original English.
|