aboutsummaryrefslogtreecommitdiff
path: root/gdb/spu-tdep.c
diff options
context:
space:
mode:
Diffstat (limited to 'gdb/spu-tdep.c')
-rw-r--r--gdb/spu-tdep.c142
1 files changed, 140 insertions, 2 deletions
diff --git a/gdb/spu-tdep.c b/gdb/spu-tdep.c
index 1cc77ad..7e7ab9c 100644
--- a/gdb/spu-tdep.c
+++ b/gdb/spu-tdep.c
@@ -42,6 +42,7 @@
#include "floatformat.h"
#include "block.h"
#include "observer.h"
+#include "infcall.h"
#include "spu-tdep.h"
@@ -52,6 +53,8 @@ static struct cmd_list_element *showspucmdlist = NULL;
/* Whether to stop for new SPE contexts. */
static int spu_stop_on_load_p = 0;
+/* Whether to automatically flush the SW-managed cache. */
+static int spu_auto_flush_cache_p = 1;
/* The tdep structure. */
@@ -340,7 +343,8 @@ spu_register_reggroup_p (struct gdbarch *gdbarch, int regnum,
return default_register_reggroup_p (gdbarch, regnum, group);
}
-/* Address conversion. */
+
+/* Address handling. */
static int
spu_gdbarch_id (struct gdbarch *gdbarch)
@@ -377,6 +381,37 @@ spu_lslr (int id)
return strtoulst (buf, NULL, 16);
}
+static int
+spu_address_class_type_flags (int byte_size, int dwarf2_addr_class)
+{
+ if (dwarf2_addr_class == 1)
+ return TYPE_INSTANCE_FLAG_ADDRESS_CLASS_1;
+ else
+ return 0;
+}
+
+static const char *
+spu_address_class_type_flags_to_name (struct gdbarch *gdbarch, int type_flags)
+{
+ if (type_flags & TYPE_INSTANCE_FLAG_ADDRESS_CLASS_1)
+ return "__ea";
+ else
+ return NULL;
+}
+
+static int
+spu_address_class_name_to_type_flags (struct gdbarch *gdbarch,
+ const char *name, int *type_flags_ptr)
+{
+ if (strcmp (name, "__ea") == 0)
+ {
+ *type_flags_ptr = TYPE_INSTANCE_FLAG_ADDRESS_CLASS_1;
+ return 1;
+ }
+ else
+ return 0;
+}
+
static void
spu_address_to_pointer (struct gdbarch *gdbarch,
struct type *type, gdb_byte *buf, CORE_ADDR addr)
@@ -396,6 +431,10 @@ spu_pointer_to_address (struct gdbarch *gdbarch,
ULONGEST addr
= extract_unsigned_integer (buf, TYPE_LENGTH (type), byte_order);
+ /* Do not convert __ea pointers. */
+ if (TYPE_ADDRESS_CLASS_1 (type))
+ return addr;
+
return addr? SPUADDR (id, addr & lslr) : 0;
}
@@ -1820,6 +1859,73 @@ spu_catch_start (struct objfile *objfile)
}
+/* Look up OBJFILE loaded into FRAME's SPU context. */
+static struct objfile *
+spu_objfile_from_frame (struct frame_info *frame)
+{
+ struct gdbarch *gdbarch = get_frame_arch (frame);
+ struct gdbarch_tdep *tdep = gdbarch_tdep (gdbarch);
+ struct objfile *obj;
+
+ if (gdbarch_bfd_arch_info (gdbarch)->arch != bfd_arch_spu)
+ return NULL;
+
+ ALL_OBJFILES (obj)
+ {
+ if (obj->sections != obj->sections_end
+ && SPUADDR_SPU (obj_section_addr (obj->sections)) == tdep->id)
+ return obj;
+ }
+
+ return NULL;
+}
+
+/* Flush cache for ea pointer access if available. */
+static void
+flush_ea_cache (void)
+{
+ struct minimal_symbol *msymbol;
+ struct objfile *obj;
+
+ if (!has_stack_frames ())
+ return;
+
+ obj = spu_objfile_from_frame (get_current_frame ());
+ if (obj == NULL)
+ return;
+
+ /* Lookup inferior function __cache_flush. */
+ msymbol = lookup_minimal_symbol ("__cache_flush", NULL, obj);
+ if (msymbol != NULL)
+ {
+ struct type *type;
+ CORE_ADDR addr;
+
+ type = objfile_type (obj)->builtin_void;
+ type = lookup_function_type (type);
+ type = lookup_pointer_type (type);
+ addr = SYMBOL_VALUE_ADDRESS (msymbol);
+
+ call_function_by_hand (value_from_pointer (type, addr), 0, NULL);
+ }
+}
+
+/* This handler is called when the inferior has stopped. If it is stopped in
+ SPU architecture then flush the ea cache if used. */
+static void
+spu_attach_normal_stop (struct bpstats *bs, int print_frame)
+{
+ if (!spu_auto_flush_cache_p)
+ return;
+
+ /* Temporarily reset spu_auto_flush_cache_p to avoid recursively
+ re-entering this function when __cache_flush stops. */
+ spu_auto_flush_cache_p = 0;
+ flush_ea_cache ();
+ spu_auto_flush_cache_p = 1;
+}
+
+
/* "info spu" commands. */
static void
@@ -2411,6 +2517,14 @@ show_spu_stop_on_load (struct ui_file *file, int from_tty,
value);
}
+static void
+show_spu_auto_flush_cache (struct ui_file *file, int from_tty,
+ struct cmd_list_element *c, const char *value)
+{
+ fprintf_filtered (file, _("Automatic software-cache flush is %s.\n"),
+ value);
+}
+
/* Set up gdbarch struct. */
@@ -2480,10 +2594,16 @@ spu_gdbarch_init (struct gdbarch_info info, struct gdbarch_list *arches)
set_gdbarch_double_format (gdbarch, floatformats_ieee_double);
set_gdbarch_long_double_format (gdbarch, floatformats_ieee_double);
- /* Address conversion. */
+ /* Address handling. */
set_gdbarch_address_to_pointer (gdbarch, spu_address_to_pointer);
set_gdbarch_pointer_to_address (gdbarch, spu_pointer_to_address);
set_gdbarch_integer_to_address (gdbarch, spu_integer_to_address);
+ set_gdbarch_address_class_type_flags (gdbarch, spu_address_class_type_flags);
+ set_gdbarch_address_class_type_flags_to_name
+ (gdbarch, spu_address_class_type_flags_to_name);
+ set_gdbarch_address_class_name_to_type_flags
+ (gdbarch, spu_address_class_name_to_type_flags);
+
/* Inferior function calls. */
set_gdbarch_call_dummy_location (gdbarch, ON_STACK);
@@ -2536,6 +2656,9 @@ _initialize_spu_tdep (void)
/* Install spu stop-on-load handler. */
observer_attach_new_objfile (spu_catch_start);
+ /* Add ourselves to normal_stop event chain. */
+ observer_attach_normal_stop (spu_attach_normal_stop);
+
/* Add root prefix command for all "set spu"/"show spu" commands. */
add_prefix_cmd ("spu", no_class, set_spu_command,
_("Various SPU specific commands."),
@@ -2559,6 +2682,21 @@ Use \"off\" to disable stopping for new SPE threads."),
show_spu_stop_on_load,
&setspucmdlist, &showspucmdlist);
+ /* Toggle whether or not to automatically flush the software-managed
+ cache whenever SPE execution stops. */
+ add_setshow_boolean_cmd ("auto-flush-cache", class_support,
+ &spu_auto_flush_cache_p, _("\
+Set whether to automatically flush the software-managed cache."),
+ _("\
+Show whether to automatically flush the software-managed cache."),
+ _("\
+Use \"on\" to automatically flush the software-managed cache\n\
+whenever SPE execution stops.\n\
+Use \"off\" to never automatically flush the software-managed cache."),
+ NULL,
+ show_spu_auto_flush_cache,
+ &setspucmdlist, &showspucmdlist);
+
/* Add root prefix command for all "info spu" commands. */
add_prefix_cmd ("spu", class_info, info_spu_command,
_("Various SPU specific commands."),