aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--gdb/doc/ChangeLog5
-rw-r--r--gdb/doc/gdb.texinfo42
2 files changed, 28 insertions, 19 deletions
diff --git a/gdb/doc/ChangeLog b/gdb/doc/ChangeLog
index 72dcb4f..03a704b 100644
--- a/gdb/doc/ChangeLog
+++ b/gdb/doc/ChangeLog
@@ -1,3 +1,8 @@
+2000-03-28 J.T. Conklin <jtc@redback.com>
+
+ * gdb.texinfo: Clarify which remote debug protocol commands are
+ required and which are optional.
+
Tue Mar 28 16:06:22 2000 Andrew Cagney <cagney@b1.cygnus.com>
* gdb.texinfo: Revert remainder of Fri Mar 24 18:06:34 2000 Andrew
diff --git a/gdb/doc/gdb.texinfo b/gdb/doc/gdb.texinfo
index 82482d0..6aca7ad 100644
--- a/gdb/doc/gdb.texinfo
+++ b/gdb/doc/gdb.texinfo
@@ -8938,6 +8938,10 @@ For any @var{command} not supported by the stub, an empty response
protocol. A newer @value{GDBN} can tell if a packet is supported based
on that response.
+A stub is required to support the @samp{g}, @samp{G}, @samp{m}, @samp{M},
+@samp{c}, and @samp{s} @var{command}s. All other @var{command}s are
+optional.
+
Below is a complete list of all currently defined @var{command}s and
their corresponding response @var{data}:
@@ -8946,7 +8950,7 @@ their corresponding response @var{data}:
@tab Request
@tab Description
-@item extended ops @emph{(optional)}
+@item extended ops
@tab @code{!}
@tab
Use the extended remote protocol. Sticky---only needs to be set once.
@@ -8972,7 +8976,7 @@ and continue.
@tab @code{a}
@tab Reserved for future use
-@item set program arguments @strong{(reserved)} @emph{(optional)}
+@item set program arguments @strong{(reserved)}
@tab @code{A}@var{arglen}@code{,}@var{argnum}@code{,}@var{arg}@code{,...}
@tab
Initialized @samp{argv[]} array passed into program. @var{arglen}
@@ -9012,7 +9016,7 @@ current address.
@tab reply
@tab see below
-@item continue with signal @emph{(optional)}
+@item continue with signal
@tab @code{C}@var{sig}@code{;}@var{addr}
@tab
Continue with signal @var{sig} (hex signal number). If
@@ -9026,7 +9030,7 @@ Continue with signal @var{sig} (hex signal number). If
@tab
toggle debug flag.
-@item detach @emph{(optional)}
+@item detach
@tab @code{D}
@tab
Detach @value{GDBN} from the remote system. Sent to the remote target before
@@ -9083,7 +9087,7 @@ See @samp{g} for a description of the @var{XX...} data.
@tab @code{h}
@tab Reserved for future use
-@item set thread @emph{(optional)}
+@item set thread
@tab @code{H}@var{c}@var{t...}
@tab
Set thread for subsequent operations (@samp{m}, @samp{M}, @samp{g},
@@ -9112,14 +9116,14 @@ thread used in other operations. If zero, pick a thread, any thread.
@c selected, sets the registers of the register block of
@c that thread; otherwise sets current registers.
-@item cycle step @strong{(draft)} @emph{(optional)}
+@item cycle step @strong{(draft)}
@tab @code{i}@var{addr}@code{,}@var{nnn}
@tab
Step the remote target by a single clock cycle. If @code{,}@var{nnn} is
present, cycle step @var{nnn} cycles. If @var{addr} is present, cycle
step starting at that address.
-@item signal then cycle step @strong{(reserved)} @emph{(optional)}
+@item signal then cycle step @strong{(reserved)}
@tab @code{I}
@tab
See @samp{i} and @samp{S} for likely syntax and semantics.
@@ -9132,7 +9136,7 @@ See @samp{i} and @samp{S} for likely syntax and semantics.
@tab @code{J}
@tab Reserved for future use
-@item kill request @emph{(optional)}
+@item kill request
@tab @code{k}
@tab
FIXME: @emph{There is no description of how operate when a specific
@@ -9202,7 +9206,7 @@ See write register.
@tab return @var{r....}
@tab The hex encoded value of the register in target byte order.
-@item write reg @emph{(optional)}
+@item write reg
@tab @code{P}@var{n...}@code{=}@var{r...}
@tab
Write register @var{n...} with value @var{r...}, which contains two hex
@@ -9214,7 +9218,7 @@ digits for each byte in the register (target byte order).
@tab reply @code{E}@var{NN}
@tab for an error
-@item general query @emph{(optional)}
+@item general query
@tab @code{q}@var{query}
@tab
Request info about @var{query}. In general @value{GDBN} @var{query}'s
@@ -9232,7 +9236,7 @@ must ensure that they match the full @var{query} name.
@tab reply @samp{}
@tab Indicating an unrecognized @var{query}.
-@item general set @emph{(optional)}
+@item general set
@tab @code{Q}@var{var}@code{=}@var{val}
@tab
Set value of @var{var} to @var{val}. See @samp{q} for a discussing of
@@ -9243,14 +9247,14 @@ naming conventions.
@tab
Reset the entire system.
-@item remote restart @emph{(optional)}
+@item remote restart
@tab @code{R}@var{XX}
@tab
Restart the remote server. @var{XX} while needed has no clear
definition. FIXME: @emph{An example interaction explaining how this
packet is used in extended-remote mode is needed}.
-@item step @emph{(optional)}
+@item step
@tab @code{s}@var{addr}
@tab
@var{addr} is address to resume. If @var{addr} is omitted, resume at
@@ -9259,7 +9263,7 @@ same address.
@tab reply
@tab see below
-@item step with signal @emph{(optional)}
+@item step with signal
@tab @code{S}@var{sig}@code{;}@var{addr}
@tab
Like @samp{C} but step not continue.
@@ -9267,14 +9271,14 @@ Like @samp{C} but step not continue.
@tab reply
@tab see below
-@item search @emph{(optional)}
+@item search
@tab @code{t}@var{addr}@code{:}@var{PP}@code{,}@var{MM}
@tab
Search backwards starting at address @var{addr} for a match with pattern
@var{PP} and mask @var{MM}. @var{PP} and @var{MM} are 4
bytes. @var{addr} must be at least 3 digits.
-@item thread alive @emph{(optional)}
+@item thread alive
@tab @code{T}@var{XX}
@tab Find out if the thread XX is alive.
@item
@@ -9312,7 +9316,7 @@ bytes. @var{addr} must be at least 3 digits.
@tab @code{x}
@tab Reserved for future use
-@item write mem (binary) @emph{(optional)}
+@item write mem (binary)
@tab @code{X}@var{addr}@code{,}@var{length}@var{:}@var{XX...}
@tab
@var{addr} is address, @var{length} is number of bytes, @var{XX...} is
@@ -9333,12 +9337,12 @@ escaped using @code{0x7d}.
@tab @code{Y}
@tab Reserved for future use
-@item remove break or watchpoint @strong{(draft)} @emph{(optional)}
+@item remove break or watchpoint @strong{(draft)}
@tab @code{z}@var{t}@code{,}@var{addr}@code{,}@var{length}
@tab
See @samp{Z}.
-@item insert break or watchpoint @strong{(draft)} @emph{(optional)}
+@item insert break or watchpoint @strong{(draft)}
@tab @code{Z}@var{t}@code{,}@var{addr}@code{,}@var{length}
@tab
@var{t} is type: @samp{0} - software breakpoint, @samp{1} - hardware