authorPeter Bergner <bergner@vnet.ibm.com>2008-08-02 04:38:51 +0000
committerPeter Bergner <bergner@vnet.ibm.com>2008-08-02 04:38:51 +0000
commit9b4e57660d385d9135549aeb8360ebfa14fb3990 (patch)
treee508e99bbab020f78ccd3b320ca8bf30b1b95b96 /gas/config
parentdbe454a3b5f62a101aa4a8b290a7c63a40f8ac52 (diff)
downloadgdb-9b4e57660d385d9135549aeb8360ebfa14fb3990.zip
gdb-9b4e57660d385d9135549aeb8360ebfa14fb3990.tar.gz
gdb-9b4e57660d385d9135549aeb8360ebfa14fb3990.tar.bz2
gas/
* config/tc-ppc.c (parse_cpu): Rename altivec_or_spe to retain_flags. Handle -mvsx and -mpower7. (md_show_usage): Document -mpower7 and -mvsx. * doc/as.texinfo (Target PowerPC): Document -mvsx. * doc/c-ppc.texi (PowerPC-Opts): Document -mvsx and -mpower7. gas/testsuite/ * gas/ppc/power7.d: New. * gas/ppc/power7.s: Likewise. * gas/ppc/ppc.exp: Run power7 test. include/opcode/ * ppc.h (PPC_OPCODE_VSX, PPC_OPERAND_VSR): New. opcodes/ * ppc-dis.c (powerpc_init_dialect): Handle power7 and vsx options. (print_insn_powerpc): Prepend 'vs' when printing VSX registers. (print_ppc_disassembler_options): Document -Mpower7 and -Mvsx. * ppc-opc.c (insert_xt6): New static function. (extract_xt6): Likewise. (insert_xa6): Likewise. (extract_xa6: Likewise. (insert_xb6): Likewise. (extract_xb6): Likewise. (insert_xb6s): Likewise. (extract_xb6s): Likewise. (XS6, XT6, XA6, XB6, XB6S, DM, XX3, XX3DM, XX1_MASK, XX3_MASK, XX3DM_MASK, PPCVSX): New. (powerpc_opcodes): Add opcodes "lxvd2x", "lxvd2ux", "stxvd2x", "stxvd2ux", "xxmrghd", "xxmrgld", "xxpermdi", "xvmovdp", "xvcpsgndp".
Diffstat (limited to 'gas/config')
-rw-r--r--gas/config/tc-ppc.c27
1 files changed, 22 insertions, 5 deletions
diff --git a/gas/config/tc-ppc.c b/gas/config/tc-ppc.c
index bded5f3..76a9e8e 100644
--- a/gas/config/tc-ppc.c
+++ b/gas/config/tc-ppc.c
@@ -825,7 +825,8 @@ const size_t md_longopts_size = sizeof (md_longopts);
static int
parse_cpu (const char *arg)
{
- ppc_cpu_t altivec_or_spe = ppc_cpu & (PPC_OPCODE_ALTIVEC | PPC_OPCODE_SPE);
+ ppc_cpu_t retain_flags =
+ ppc_cpu & (PPC_OPCODE_ALTIVEC | PPC_OPCODE_VSX | PPC_OPCODE_SPE);
/* -mpwrx and -mpwr2 mean to assemble for the IBM POWER/2
(RIOS2). */
@@ -873,7 +874,14 @@ parse_cpu (const char *arg)
if (ppc_cpu == 0)
ppc_cpu = PPC_OPCODE_PPC | PPC_OPCODE_CLASSIC;
- altivec_or_spe |= PPC_OPCODE_ALTIVEC;
+ retain_flags |= PPC_OPCODE_ALTIVEC;
+ }
+ else if (strcmp (arg, "vsx") == 0)
+ {
+ if (ppc_cpu == 0)
+ ppc_cpu = PPC_OPCODE_PPC | PPC_OPCODE_CLASSIC;
+
+ retain_flags |= PPC_OPCODE_VSX;
}
else if (strcmp (arg, "e500") == 0 || strcmp (arg, "e500x2") == 0)
{
@@ -893,7 +901,7 @@ parse_cpu (const char *arg)
if (ppc_cpu == 0)
ppc_cpu = PPC_OPCODE_PPC | PPC_OPCODE_EFS;
- altivec_or_spe |= PPC_OPCODE_SPE;
+ retain_flags |= PPC_OPCODE_SPE;
}
/* -mppc64 and -m620 mean to assemble for the 64-bit PowerPC
620. */
@@ -935,6 +943,13 @@ parse_cpu (const char *arg)
| PPC_OPCODE_POWER5 | PPC_OPCODE_POWER6
| PPC_OPCODE_ALTIVEC);
}
+ else if (strcmp (arg, "power7") == 0)
+ {
+ ppc_cpu = (PPC_OPCODE_PPC | PPC_OPCODE_CLASSIC
+ | PPC_OPCODE_64 | PPC_OPCODE_POWER4
+ | PPC_OPCODE_POWER5 | PPC_OPCODE_POWER6
+ | PPC_OPCODE_ALTIVEC | PPC_OPCODE_VSX);
+ }
else if (strcmp (arg, "cell") == 0)
{
ppc_cpu = (PPC_OPCODE_PPC | PPC_OPCODE_CLASSIC
@@ -952,8 +967,8 @@ parse_cpu (const char *arg)
else
return 0;
- /* Make sure the the Altivec and SPE bits are not lost. */
- ppc_cpu |= altivec_or_spe;
+ /* Make sure the the Altivec, VSX and SPE bits are not lost. */
+ ppc_cpu |= retain_flags;
return 1;
}
@@ -1139,11 +1154,13 @@ PowerPC options:\n\
-mpower4 generate code for Power4 architecture\n\
-mpower5 generate code for Power5 architecture\n\
-mpower6 generate code for Power6 architecture\n\
+-mpower7 generate code for Power7 architecture\n\
-mcell generate code for Cell Broadband Engine architecture\n\
-mcom generate code Power/PowerPC common instructions\n\
-many generate code for any architecture (PWR/PWRX/PPC)\n"));
fprintf (stream, _("\
-maltivec generate code for AltiVec\n\
+-mvsx generate code for Vector-Scalar (VSX) instructions\n\
-me300 generate code for PowerPC e300 family\n\
-me500, -me500x2 generate code for Motorola e500 core complex\n\
-me500mc, generate code for Freescale e500mc core complex\n\