authorShivamurthy Shastri <sshivamurthy@micron.com>2020-07-07 22:04:11 +0200
committerJagan Teki <jagan@amarulasolutions.com>2020-07-20 22:28:33 +0530
commit720fcb27e0be500a718fffd9c1910f8ed94e7745 (patch)
tree318d2f24a27faf9100ec8968c7adef3472b44563 /drivers/mtd/nand/spi
parent5cf049c00ac0c5c9542ce968d9f79451ce870b2c (diff)
downloadu-boot-720fcb27e0be500a718fffd9c1910f8ed94e7745.zip
u-boot-720fcb27e0be500a718fffd9c1910f8ed94e7745.tar.gz
u-boot-720fcb27e0be500a718fffd9c1910f8ed94e7745.tar.bz2
mtd: spinand: micron: identify SPI NAND device with Continuous Read mode
Add SPINAND_HAS_CR_FEAT_BIT flag to identify the SPI NAND device with the Continuous Read mode. Some of the Micron SPI NAND devices have the "Continuous Read" feature enabled by default, which does not fit the subsystem needs. In this mode, the READ CACHE command doesn't require the starting column address. The device always output the data starting from the first column of the cache register, and once the end of the cache register reached, the data output continues through the next page. With the continuous read mode, it is possible to read out the entire block using a single READ command, and once the end of the block reached, the output pins become High-Z state. However, during this mode the read command doesn't output the OOB area. Hence, we disable the feature at probe time. Signed-off-by: Shivamurthy Shastri <sshivamurthy@micron.com> Acked-by: Jagan Teki <jagan@amarulasolutions.com>
Diffstat (limited to 'drivers/mtd/nand/spi')
-rw-r--r--drivers/mtd/nand/spi/micron.c16
1 files changed, 16 insertions, 0 deletions
diff --git a/drivers/mtd/nand/spi/micron.c b/drivers/mtd/nand/spi/micron.c
index c58082c..508088b 100644
--- a/drivers/mtd/nand/spi/micron.c
+++ b/drivers/mtd/nand/spi/micron.c
@@ -22,6 +22,8 @@
#define MICRON_STATUS_ECC_4TO6_BITFLIPS (3 << 4)
#define MICRON_STATUS_ECC_7TO8_BITFLIPS (5 << 4)
+#define MICRON_CFG_CR BIT(0)
+
static SPINAND_OP_VARIANTS(read_cache_variants,
SPINAND_PAGE_READ_FROM_CACHE_QUADIO_OP(0, 2, NULL, 0),
SPINAND_PAGE_READ_FROM_CACHE_X4_OP(0, 1, NULL, 0),
@@ -157,8 +159,22 @@ static int micron_spinand_detect(struct spinand_device *spinand)
return 1;
}
+static int micron_spinand_init(struct spinand_device *spinand)
+{
+ /*
+ * M70A device series enable Continuous Read feature at Power-up,
+ * which is not supported. Disable this bit to avoid any possible
+ * failure.
+ */
+ if (spinand->flags & SPINAND_HAS_CR_FEAT_BIT)
+ return spinand_upd_cfg(spinand, MICRON_CFG_CR, 0);
+
+ return 0;
+}
+
static const struct spinand_manufacturer_ops micron_spinand_manuf_ops = {
.detect = micron_spinand_detect,
+ .init = micron_spinand_init,
};
const struct spinand_manufacturer micron_spinand_manufacturer = {